HOW TO CUSTOMIZE SETTINGS
UP - Press button to increase setting
DOWN - Press button to decrease setting
ENTER/RESET - Press button, hold for 3 seconds to restart timer or to adjust the setting. The timer will
always start in the "ON" cycle.
TEMPERATURE DISPLAY - Press and hold both the UP and DOWN button for 3 seconds to change
display. C for Celsius and F for Fahrenheit.
DAYTIME SETTING - To set the Day temperature press the TEMP DAYTIME SETTING, dAY__F will be
displayed. To change settings press the UP and DOWN buttons. Press ENTER to accept new setting.
NIGHT SETTING - To set the Night temperature press TEMP NIGHT SETTING button, Nit__F will be
displayed. To change settings press the UP and DOWN buttons. Press ENTER to accept new setting.
TEMP DEADBAND – Press this button to change the Temp deadband. To set the deadband, press
TEMP DEAD BAND. d.b_ _ _F will be displayed. To change settings, press the UP and DOWN buttons.
Press ENTER to accept new setting.
HUMIDITY SETTING - There is a day humidity setting and a night humidity setting.
• To set the daytime humidity, press the HUMIDITY SETTING button. day_rH will be displayed.
Press the UP or DOWN button to change daytime humidity setting. Press ENTER to accept new
setting.
• To set the nighttime humidity, press the HUMIDITY SETTING button a second time nit_rH will be
displayed. Press the UP or DOWN button to change the nighttime humidity setting. Press ENTER
to accept new setting.
HUMIDITY MODE – Use this button to select humidify or dehumidify. Press Humidity mode and the
display will read the current setting, either humidify (rH Incr) or dehumidify (rH dEcr). Press the UP
and DOWN buttons to change the setting. Press ENTER to accept new setting.
HUMIDITY DEADBAND - Pressing HUMIDITY DEAD BAND will display the current setting. Press the
UP or DOWN buttons to change the setting. Press ENTER to accept new setting.
CO
ON TIME - To change the timer settings, press the UP or DOWN button to change hours setting
2
(left 2 digits) then press ENTER to change to the minutes (center 2 digits), use UP or DOWN to change,
then press ENTER to advance to the seconds setting (right 2 digits). Pressing ENTER a final time accepts
the new settings.
CO
OFF TIME - Repeat the procedure above to change the CO
2
TEMP/HUMIDITY LOCK - Use this function to interlock (COnnEct) or split (SPLit) humidity and
temperature. Press Temp/humidity lock button to display the setting. Press the UP and DOWN buttons
to change the setting. Press ENTER to accept new setting.
1. Select connect (COnnEct) if using ventilating fans only for cooling and removing humidity. The
fan will turn on when the sensor detects a rise above the setting in either the humidity or
temperature.
2. Select split (SPLit) if using a ventilating fan or AC unit as a cooling device and a dehumidifier to
remove humidity. Each device is controlled independently. The cooling device will turn on when
the temperature rises above the setting and the dehumidifier will turn on when the humidity rises
above the setting.
INSTRUCTIONS
OFF timer settings.
2
5