flashing to indicate which device may have a problem.
This safety feature is extremely important and useful to eliminate "runaway" conditions which could
result in crop damage or other more serious problems.
If any of the error LEDs are blinking, the user should refer to the example below to help identify the
actual cause of the error.
EXAMPLE: If the Cooling error LED is flashing, it means that the device connected to the Cooling
output either did not turn on OR that there is a problem with the temperature sensor. Check the
cooling device for proper operation and verify that the remote sensor is reading properly.
NOTE: To reset an error, press the ENTER/RESET button.

FACTORY SETTINGS

The APCETHD comes pre-programmed with factory settings. These settings may be adjusted by the
user. For best results, verify changes after adjusting any settings. The controller can be easily reset to
factory settings. (See below)
Temp day settings
Temp night setting
Temp dead-band
Humid settings
Humid mode
Humid dead-band
CO
Mode
2
CO
ON timer
2
CO
OFF timer
2
Temp & humid lock
RESET FACTORY SETTINGS - Press and hold the ENTER/RESET and DOWN buttons together for 3
seconds. The display will read f.Set. Press the ENTER/RESET button again to restore the factory default
settings. When the factory reset is complete, the unit will say donE.
NOTE: To change the temperature reading from F to C, press and hold the UP and DOWN buttons
for 2-3 seconds.
OVERVIEW
• The individual push-buttons on the
APCETHD make changing settings EASY.
• Press a button, and the display shows the
current setting.
• To change the settings, use the UP and
DOWN buttons.
• Then press ENTER to accept the new setting.
4
www.hydrofarm.com
INSTRUCTIONS
80°F
70°F
3°F
50% rH
Rh decr
5% rH
DayFree
1 minute
30 minutes
Split