ENGLISH
LED
Keypad state LED (blue/amber):
Blue LED on for 5 seconds: the system is in normal operating mode.
The blue LED blinks for 5 seconds: it indicates flat battery in normal operating mode.
Amber LED on: the system is in test mode.
Amber LED blinking: in Test mode, this indicates flat battery.
<
<
N
N
O
O
T
T
E
E
>
>
When it is not used, the keypad goes to sleep mode and all LEDs are off. When a button is pressed, the blue keypad
state LED lights up for five seconds to indicate that the remote keypad is active.
The blue LED switches off after a sequence has been entered correctly or if longer than 5 seconds elapse between the
pressing of two buttons.
If the blue LED switches off before having entered the complete sequence, the previously pressed buttons will be ignored.
System state LED (blue/red):
Red LED on: the system is in Total Armed state.
Red LED blinking: the system is in Partial Armed state.
Blue LED on: the system is off.
Blue LED blinking: error for the following reasons:
No reply sent to control unit within 4 seconds.
Incorrect error code. If an incorrect disarming code is entered five times, the system will be blocked and the
keypad will be deactivated for approximately 9 minutes, during which normal operation cannot be restored
even if the correct disarming code is entered or by operating from the app and portal ("Key locked" will appear
in the "Event Log" on the local control panel). Repeating an incorrect code will extend the time by 9 more
minutes.
Request to pass to Partial Armed state when the Total Armed state.
Forced arming request.
Fault LED (amber):
Blinking: system error (control unit tamper, power fault, detector tamper, detector fault, door open, etc.)
On: alarms have occurred.
Test mode
The remote keypad may be set to Test mode by entering the keypad code (default: 0000) followed by button *. The amber state
LED lights up and a long beep will sound.
To exit Test mode, press the button twice
off and the remote keypad will return to normal operating mode. Otherwise, the remote keypad will automatically shut down Test
mode after 5 minutes and go back to normal operating mode.
<
N
O
T
E
>
<
N
O
T
E
>
Test mode is useful to exclude the tamper alarm of the remote keypad during installation, during battery replacement or if
it is moved to another installation site.
When the remote keypad is in Test mode it is always active and will NOT switch off automatically after 5 seconds.
Test mode operation:
QUICK GUIDE
KP600
LED REMOTE KEYPAD
17
, the remote keypad will generate a long beep, the keypad state LED will be switched
DS80KP55-002
1. Keypad state LED
2. System state LED
3. Fault LED
4. Arming button
5. Partial arming button
6. Button
7. Disarming button
8. Button #
9. Button
10. Learn data buttons
11. Not used
12. Not used
13. Panic alarm buttons (if
enabled)
14. Battery isolator
15. Mounting holes
16. Tamper switch
17. Closing screw