Technical Specifications - Munters JAZ Serie Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Compressor Pressure Adjustment - JAZ 10 D/20 D/20
DW/30 D/40 D (for qualified persons only) (Fig. 12)
The compressor pressure is factory set and must be
checked and adjusted only by qualified personnel , using a
pressure gauge. Tampering or improper setting changes
by the operator
may cause incorrect combustion,
dangerous emissions and hazardous situations.
Note: the following information are intended for qualified
personnel only.
To check and adjust the pressure in case of malfunctions
proceed as follows: Unscrew pressure port cap (1). Connect a
0-0.6 bar pressure gauge on the pressure measuring port (1)
on the rear guard. Start heater and read air pressure value. If
necessary adjust pressure to the correct value turning the
adjusting screw (2) clockwise to increase, or anti
counterclockwise to decrease the pressure:
Model
Air Pressure (bar)
JAZ 10 D
0.32
JAZ 20 DH
0.28
JAZ 20 DW
0.28
JAZ 30 D
0.32
JAZ 40 D
0.34

7. Technical Specifications

Model
Heat Input [kW] [Hs]
Air Flow Rating [m³/h]
Fuel Type
Fuel consumption [l/h]
Fuel Nozzle Size
Voltage [V]
Electrical Power [W]
Air Pressure Setting
[bar]
Fuel Pressure Setting
[bar]
Current Rating [A]
Fuse rating
Dimensions
Net Weight [kg]
Length [mm]
Width [mm]
Height [mm]
Tank Capacity [l]
Running Time [h]
Standard
Accessories
Fuel Level Indicator
Power Cord Support
Handle
Ambient Thermostat
Error Indicator
Operational Range
Ambient Temperature
Range
© Munters 2013
10 D
20 DH
11.53
21.49
270
Diesel -
Diesel -
Kerosene
Kerosene
1.1
0.30 gph
0.65 gph
230V 50Hz
230V 50Hz
170
0.32
0.28
-
0.80
0.90
T 3.15 A
T 3.15 A
12
670
319
418
19
~18
Sightglass
Sightglass
yes
1 (plastic)
1 (plastic)
built-in
built-in
yes
Munters reserves the right to make alterations to specifications, quantities, etc. for production or other reasons, subsequent to publication
GB
Fuel Pump Pressure Adjustment (JAZ 60 D)
The fuel pump pressure is factory set and must be
checked and adjusted by qualified service personnel only.
Tampering with the unit may cause incorrect combustion
and dangerous emissions.
Model
JAZ 60 D
Electrical parts
Every year, before seasonal use, have all internal wiring,
electrical parts and connections onspected by qualified
personnel. Clean, fix or replace parts as needed.
20 DW
21.49
420
420
Diesel -
Kerosene
2.0
2.0
0.65 gph
230V 50Hz
230V 50Hz
200
200
0.28
-
-
0.90
T 3.15 A
14
16
670
807
319
404
418
608
19
19
~10
~10
Sightglass
Fuel gauge
yes
yes
1 (metal)
built-in
yes
yes
-20°C ÷ 30°C
JAZ
Fig. 12
Fuel Pump Pressure (bar)
12
30 D
40 D
30.74
41.08
570
630
Diesel -
Diesel -
Kerosene
Kerosene
2.9
3.8
0.85 gph
1.00 gph
230V 50Hz
240
300
0.32
0.34
-
-
1.05
1.30
T 3.15 A
T 3.15 A
26
27
930
930
500
500
625
625
43
43
~15
~12
Fuel gauge
yes
yes
1 (metal)
1 (metal)
built-in
built-in
yes
yes
.
60 D
59.66
1550
Diesel -
Kerosene
5.5
1.25 gph
230V 50Hz
600
-
12
2.30
T 4 A
55
1262
631
760
65
~12
Fuel gauge
yes
1 (metal)
built-in
yes
9

Publicité

Table des Matières
loading

Produits Connexes pour Munters JAZ Serie

Ce manuel est également adapté pour:

Jaz 10 dJaz 20 dhJaz 20 dwJaz 30 dJaz 40 dJaz 60d

Table des Matières