HeatStar ERXL Serie Instructions D'utilisation Et Manuel Du Propriétaire page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIGURE 10: Unvented Operation
36"
(91cm)
1.
Ventilation equal to 4 CFM per 1,000 BTU/HR firing rate must
be provided in unvented heater installations
2.
For dimensions A "unvented" refer to ( Figure 1- Minimum
Clearances to Combustibles.)
FIGURE 10A: Single Wall
Single wall vent run
Single wall terminal end
18" (45cm) Min.
2"(5cm) Clearance thimble
required when flu pipe
extends through
combustible materials
A
36"
(91cm)
3'-0" (91cm) Min.
6' (182cm) Min.
Pitch flue pipe down
toward outlet 1/4" per
foot (0.6 cm per 0.3m) for
condensate drainage.
2"(5cm) Clearance thimble
Enerco | Heatstar ERXL Series Heater
FIGURE 10b: Double Wall
Double wall vent run
Double wall terminal end
8"(20cm) to 10"(25cm) Max.
FIGURE 11: Vertical Venting
E-16
Operating Instructions and Owner's Manual
18" (45cm) Min. 3'-0" (91cm) Min.
6' (182cm) Min.
Pitch flue pipe down
toward outlet 1/4" per
foot (0.6 cm per 0.3m) for
condensate drainage.
18" (45cm)

Publicité

Table des Matières
loading

Table des Matières