KRATOS SAFETY KS Serie Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

COMPONENTS FOR LIGHT STRUCTURES:
As 'lightweight' receiving structures such as steel box section and standing seam roofs are not as strong, additional precautions must be taken when
sizing the device. Taking the mandatory 2x safety margin into account, the forces transmitted to the structure when supporting workers and arresting
falls must be reduced so as not to exceed the load these materials can accommodate, namely 7.5 kN.
FA 60 220 00
Intermediate post for
steel box section roof
Application
Material
Weight
Breaking strength
Fixings
Minimum box section
thickness
STEEL BOX SECTION ROOFS:
Anchorage post for
steel box section
roof
Application
Material
Weight
Breaking strength
Fixings
Minimum box
section thickness
Conformity
FA 60 220 00
Used for fixing FA 60 204 00 intermediate loops.
Attachment plate with several holes to accom-
modate different dimensions (see spacing dimen-
sions). Comes with EPDM waterproofing strips.
Designed to dissipate part of the energy generated
when a fall is arrested.
3.19 kg
Attaches to a steel box section roof with 16 rivets.
FA 60 219 00
Lifeline end piece
Attachment plate with several holes to accommodate different dimen-
sions (see spacing dimensions). Comes with EPDM waterproofing strips.
Designed to dissipate part of the energy generated when a fall is arrested.
316 stainless steel
3.4 kg
> 15 kN
Attaches to a steel box section roof with 16 rivets.
0.5 mm
EN 795:2012 Type A
FA 60 221 00
Used for going around 90° corners. Attachment
plate with several holes to accommodate different
dimensions (see spacing dimensions). Comes with
EPDM waterproofing strips.
316 stainless steel
> 15 kN
0.5 mm
39
FA 60 221 00
3.86 kg

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ks 4000

Table des Matières