Fulgor Milano M6RT601 Serie Mode D'emploi page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1 2 3 4 5
400V 3N
2
cable 5x1,5mm
R S T
N
1 2 3 4 5
230V
2
cable 3x2,5mm
R
N
min. 15 mm
min.40
min.70
+0
560
-4
490
Installation
in
worktop
As far as fire hazard protection is
concerned, this apparatus can be fitted
also close to wooden walls that are
higher than the surface on which it is
installed, provided a minimum clea-
rance of 70 mm is maintained between
the apparatus and the side walls, and
a clearance of 40 mm is maintained
between it and the rear wall.
To install it in the cut-out follow these
instructions:
Make a cut-out having a size shown
in fig. 2 in the kitchen worktop (fig.
2 part. 1).
Insert the hob in the cut-out and
secure it by means of the four
clamps (fig. 3 part. 1) tightening the
four screw (fig. 3 part. 2).
1 2 3 4 5
230V 3
cable 4x2,5mm
R
S
T
(2 LINES)
1 2 3 4 5
400V 2N
cable 4x1,5mm
R
S
N
Fig. 2A
20 mm
45
+0
-4
1
Fig. 2
the
kitchen
Make sure that the rubber seals
2
(fig. 3 part. 3) are properly in
place and that the mains cable is
2
not squeezed and has no narrow
bends.
3
Fig. 3
23
EN
1
2
Fig. 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M6rt60b2M6rt60s1M6rt60s2M6rt60b1

Table des Matières