MYERS 99082 Manuel Du Propriétaire page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OWNER'S MANUAL
INSPECTION
Visual inspection should be made before each use of the jack, checking for leaking hydraulic fluid and damaged, loose or missing parts Each jack must be inspected by a
manufacturer's repair facility immediately if subjected to an abnormal load or shock Any jack which appears to be damaged in any way, is found to be badly worn, or operates
abnormally MUST BE REMOVED FROM SERVICE until necessary repairs are made by a manufacturer's authorized repair facility It is recommended that an annual inspection of the
jack be made by a manufacturer's authorized repair facility and that any defective parts, decals or warning labels be replaced with manufacturer's specified parts A list of authorized
repair facilities is available from the manufacturer
PROPER STORAGE
It is recommended that the jack be stored in a dry location with all wheels touching the ground on a relatively level surface
TROUBLESHOOTING
Important: Service jacks are self-contained devices used for lifting, but not sustaining, a partial vehicular load In accordance with ASME PASE-2019 Load Sustaining Test: "A load
not less than the rated capacity...shall not lower more than 1/8" (3 18mm) in the first minute, nor a total of 1875" (4 76mm) in 10 minutes " Lowering within this range is
considered normal operation and is NOT a warrantable defect
Problem
1 Unit will not lift rated load
2 Unit will not sustain rated load or feels "spongy" under rated load
3 Unit will not lift to full height
4 Handle tends to raise up while the unit is under rated load
5 Unit still does not operate
OWNER/USER RESPONSIBILITY
The owner and/or user must have an understanding of the manufacturer's operating instructions and warnings before using this jack Personnel involved in the use and operation of
equipment shall be careful, competent, trained, and qualified in the safe operation of the equipment and its proper use when servicing motor vehicles and their components Warning
information should be emphasized and understood If the operator is not fluent in English, the manufacturer's instructions and warning shall be read to and discussed with the
operator in the operator's native language by the purchaser/owner, making sure that the operator comprehends its contents Owner and/or user must study and maintain for future
reference the manufacturers' instructions Owner and/or user is responsible for keeping all warning labels and instruction manuals legible and intact Replacement labels and literature
are available from the manufacturer
99082
Action
Purge air from hydraulic system by following procedure under SETUP
Purge air from hydraulic system as above
Purge air from hydraulic system as above
Pump the handle rapidly several times to push oil past ball valves in power unit
Contact Myers Tire Supply Customer Service
4
99082
2 TON ALUMINUM
FLOOR JACK
Rev 3/16/21