LOCKING SWITCH IN
"OFF" POSITION (FIg. 35, 36)
IMPORTANT: When the machine is not in use, the
switch should be locked in the "OFF" position to prevent
unauthorized use. To lock the machine, move the switch
toggle (OO) to the "OFF" position and pull it out of the
switch (QQ) as shown in Figure 36. With the switch toggle
(OO) removed, the switch will not operate. However,
should the switch toggle be removed while the motor is
running, the machine can be turned "OFF," but cannot be
restarted without re-inserting the switch toggle (OO).
In the event of a power outage (such as
a breaker or fuse trip), always move the switch to the
"OFF" position until the main power is restored.
FIRE HAZARD. When using this dust
collector, do not pick up anything that is burning,
smoldering, or smoking (matches, cigarettes, or hot
ashes).
EXPLOSION HAZARD. Do not use this
unit to vacuum combustible explosive materials
(coal, grain, or other finely-divided combustible
material).
HEALTH HAZARD. Do not use this
unit to vacuum hazardous, toxic, or carcinogenic
materials (asbestos, pesticide, or lead-based paint
debris).
CIRCUIT BREAKER
Your dust collector motor is supplied with a resettable circuit breaker. If the motor shuts off or fails to start due to an
overload condition, turn the dust collector switch "OFF," let the motor cool three to five minutes, and push the reset
button (RR) Fig. 35, on the circuit breaker to reset the breaker. The motor can then be turned on again in the usual
manner. If the overload continues to trip, visit our website at www.deltamachinery.com for a list of service centers or
call the DELTA Machinery help line at (800) 223-7278 (In Canada call (800) 463-3582).
For assistance with your machine, visit our website at www.deltaportercable.com for a list of service centers or call the
DELTA Machinery help line at (800) 223-7278 (In Canada call 1-800-463-3582).
To reduce the risk of injury, turn unit off and disconnect it from power source before installing and
removing accessories, before adjusting or when making repairs. An accidental start-up can cause injury.
KEEP MACHINE CLEAN
Periodically blow out all air passages with dry compressed air. All plastic parts should be cleaned with a soft damp cloth.
NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material.
Wear certified safety equipment for eye, hearing and respiratory protection while using compressed air
FAILURE TO START
Should your machine fail to start, check to make sure the prongs on the cord plug are making good contact in the outlet.
Also, check for blown fuses or open circuit breakers in the line.