OE 9000
LED LIGHTS SIGNALS
Led lights on the base of the wheelifter:
TYPE
Fixed LED
Fixed LED
Fast blinking LED
2 fast blinking + pause
Slow blinking LED
MAINTENANCE
In order to obtain a state of optimum service it is necessary to perform regular maintenance on the lift every 3
months. If the lift operates in dusty environment, it is advisable to perform maintenance more frequently.
Before performing any maintenance keep in mind that:
1) All maintenance shall be performed only by qualified persons
2) There must be no load on the lift
3) The batteries of the lift should not be placed in charge during maintenance.
4) The lift must not be connected to the main supply.
5) During the operations of maintenance and/or replacement of spare parts, the equipment and the spare parts
have to be displaced in an easily usable way and the lifter in such a way to facilitate intervention without
compromising functionality.
ATTENTION!
Before performing any maintenance operation, press the emergency button and disconnect the batteries to avoid
any risk of unexpected activation of the lift.
The following is an illustrative list of the frequency of maintenance operations
Battery charge
Cleaning
Control on power supply cable control for battery charger
Control on screws tightening
Control on wheels for transport
Control on emergency button functioning
Trapezoid screw greasing
Sliding runners greasing
Fork rollers greasing
ELECTRIC & RECHARGEABLE WHEEL LIFTER MAX. 60kg
COLOUR
Green or Yellow
Red
Red
Red
Red
MEANING
Battery charging level
Discharged Battery
Pressed emergency button
Overload of maximum loading capacity
Engine temperature too high
Daily
x
x
Every 3 month
x
x
x
x
x
x
x