Best IEX222 Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALL SUPPORT SYSTEM
1. At hood location, install 2 x 4 cross framing
between ceiling joists using dimensions
shown.
2. Finish the ceiling surface. Be sure to mark
the location of the ceiling joists and cross
framing.
3. Position the support frame so that the
support frame opening is on the long side
of the hood.
4. Secure the upper half of support frame to
joists and cross framing with four screws
(6x70mm and four washers (D.6.4mm).
Make sure screws are driven into center of
joists and framing for maximum strength.
5. Adjust the overall height of the support frame.
Loosen and re-tighten the 4 screws in the
height adjustment slots as necessary.
Insert 4 screws (3.9x9.5mm) and 4 washers
(D.4.5mm) located in the Hardware
Package.
Note that the hood height is 13¾" and that
the bottom of the hood must be 24" min. and
30" max. above the cooktop.
IN-LINE BLOWER
DRYWALL
7
/
13
16
WASHERS
(Ø6.4mm)
MOUNTING
SCREWS
(6x70mm)
FRONT
SUPPORT
FRAME
OPENING
TOP VIEW OF SUPPORT FRAME
- 6 -
CROSS FRAMING
"
SUPPORT
FRAME
HEIGHT
ADJUSTMENT SLOTS
10
/
"
7
8
CEILING
JOISTS
7
/
"
13
16

Publicité

Table des Matières
loading

Table des Matières