2. Technical data
2.1 Tank
Length
Width
Height
Weight when empty [kg]:
Nominal volume
Total weight
Environmental conditions:
Operating temperature -10 °C to +40 °C
2.2 Pump
12 V pump:
Voltage (tolerance):
Fuse:
Output: Delivery
Power consumption:
rate: Max. delivery
max. pressure:
3. Layout (with terminal clamps)
14
[cm]:
100
[cm]:
59
[cm]:
43
19,5
[l]:
100
[kg]:
103,5
CENTRI SP 30
12 VDC (± 20%)
25 A
220 W
20 A
approx. 25 l/min
1.1 bar at 12 V
c
Max. operating time:
Liquid temperature:
2.3 Delivery nozzle
Connection:
Delivery spout: Ø 23 mm
Version:
2.4 Battery
- Lithium iron phosphate battery (LiFePO
- 13.2 V – 3.3 Ah
- Battery partly charged at time of dispatch
- Charging time approx. 3 hours
- Approx. 300 litres of pump volume
per battery charge
- With integrated safety electronics
- Electrical protection type IP 67
3. Layout (with battery)
j
m
e
b
i
g
a
a
Ventilated screw cap
l
b
Delivery line ball valve
c
Electric pump CENTRI SP 30
d
in container
d
Delivery hose
e
Automatic delivery nozzle
h
f
Hose holder
g
Delivery nozzle lock
f
h
Terminal clamps
k
i
Delivery nozzle holder
j
Transport handle
k
Grip hollow
l
Recess for tensioning belts
m
On/Off switch
n
13.2 V - 3.3 Ah battery
10 min
-10 °C to +40 °C
1" female thread
with swivel joint
with automatic shut-off
)
4
m
n