Unit Function Selection - Mitsubishi Electric PAR-SL101A-E Serie Manuel D'utilisation

Masquer les pouces Voir aussi pour PAR-SL101A-E Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 75
7. Service

7.3. Unit function selection

This setting method is for Mr. Slim. For CITY MULTI models, set the DIP switches on the indoor PC
board and outdoor PC board.
To set the DIP switches, refer to the technical materials for the CITY MULTI models.
Set the functions as necessary using the remote controller. The functions for each unit can be set only
from the remote controller.
Select the functions from table 1 that must be set.
Only the refrigerant systems that are connected to indoor units equipped with wireless remote controller
receivers can be set from the wireless remote controller operation unit. The refrigerant address cannot be
specified using the wireless remote controller operation unit.
Table 1 Function selection settings (For details about the factory settings and modes of each
en
indoor unit, refer to the indoor unit installation manual.)
Note:
The items in the following table are representative examples. Because the settings for each
mode may vary depending on the model, refer to the indoor unit installation manual for details.
Mode
Power failure auto-
matic recovery
Indoor temperature
detecting
LOSSNAY
connectivity
Auto operation mode
Filter sign
Fan speed
Number of air outlets
Installed option
(high-efficiency filter, etc.)
Up/down vane setting
*3
Built-in humidifier
*1 It is available when the indoor unit is connected to any of the particular outdoor units.
*2 An optional insulation kit is required.
*3 The setting varies depending on the model.
16
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not Supported
Supported (indoor unit is not equipped with fresh air
intake)
Supported (indoor unit is equipped with fresh air intake)
Auto operation mode Single set point (Available 14°C
(58°F) cooling setting)
*1 *2
Dual set point (Not available 14°C (58°F) cooling set-
ting)
*1 *2
100Hr
2500Hr
No filter sign indicator
Silent
Standard
High ceiling
4-directional
3-directional
2-directional
Without
With
Not setting/Equipped with vanes (vanes angle setup 3)
Equipped with vanes (vanes angle setup 1)
Equipped with vanes (vanes angle setup 2)
Not equipped
Equipped
Mode no.
Setting no.
Initial setting
1
01
2
1
02
2
3
1
03
2
3
1
06
2
1
07
2
3
1
08
2
3
1
09
2
3
1
10
2
1
11
2
3
1
13
2
Setting
Select unit
number 00.
Select unit
number 01–04
or AL (all
units).

Publicité

Table des Matières
loading

Table des Matières