MoS : MOSFET
The coil of the main contactor is damaged and the brush or traction function are activated. The traction MOSFET is broken or in
short circuit : the traction is blocked. The vacuum relay has a problem, replace. Replace the traction card or check the main contactor.
Check the coil of the black traction motor relay positioned underneath the chassis.
•
MoF : Mosfet
The traction MOSFET is broken internally; the traction is blocked, brush and vacuum still works. Replace the card.
•
bLt : traction blocked
The battery voltage is too low: the traction and all other functions are blocked. Charge the batteries.
•
AcS : Brush command problem
The brush remote control switch is not engaged properly: Push the brush switch and if the error is still on the display, check the
remote control connections. If the connections are ok, replace the contactor.
•
AcA : vacuum motor command problem
The vacuum relay is not engaged properly: Push the brush switch and if the error is still on the display, check the relay connections.
If the connections are ok, replace the vacuum motor relay.
•
AcH : Water solenoid valve problem
It appear when the fuse of the solenoid valve is blown, the coil of the valve is interrupted internally or the wiring is interrupted.
•
Acl : Actuator card problem ( Only Rider)
Wrong communication between the display card and the actuator control card. Check the flat cable connection and actuator card.
•
FuP : Fuse
The coil of the main contactor does not close properly and the vacuum function is activated. Internal problem on the display card,
or incorrect contact with GND cable.
•
Clh : Clock
Internal problem in the display card memory. Replace the card.
Board Alarms
If drive is interrupted, the error code should be identified by means of the status LED (fig. 6. ref. 16). In the absence of
malfunctions, the status LED is steadily on while the machine is in operation. If a malfunction is detected, the status LED provides
two types of information, a slow flash (2 Hz) or a rapid flash (4 Hz) to indicate the severity of the malfunction.
Malfunctions with a slow flash are cancelled automatically once the malfunction has been repaired and the machine functions
normally again. Malfunctions with a rapid flash (* in the table) are considered more serious. The machine must be turned off using
the key switch (fig. 6 ref. 14) to reset operation after repairing the malfunction.
The indication of severity remains active for 10 seconds, after which the status LED flashes constantly showing a two digit malfunction
code until the repairs have been carried out.
For example, error code 1,4 is displayed as follows:
22