Water connection
 No connection is required since the appliance is filled manually.
Water drain
 Open the global valve in the bottom of the tank and discharge the water in the tank.
 Important : The tank drain must be connected to the drainage system using a pipe resistant to high temperatures
0
(100
C).
Testing the electrical system
 Switch on the appliance following the instructions for use and cheek the operation of the control devices and plate
heating elements.
 Test the various operating temperatures.
 If necessary, consult the Troubleshooting guide to identify the problem.
Testing the rated thermal power
 Always cheek the thermal power of the appliance after installation and following maintenance work.
 The rated thermal power is indicated in the "Technical data" table.
The tank heating elements do not heat up
 Check the fuses.
 Main power switch not ON.
 Low voltage or incorrect electrical connection.
 Switch faulty.
 Temperature control thermostat faulty.
 One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
The temperature control is difficult or impossible to regulate
 Temperature control thermostat faulty.
 One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
IMPORTANT : Before carrying out maintenance work or repairs, disconnect the appliance from the power supply at
the isolating switch.
Thermostat and switch
 Remove the upper control panel.
 Detach the bulb from the thermostat or switch fixed to the heating element by special support brackets.
 Disconnect the electrical connections.
 Replace the part.
START UP