Water connection
No connection is required since the appliance is filled manually.
Water drain
Open the global valve in the bottom of the tank and discharge the water in the tank.
Important : The tank drain must be connected to the drainage system using a pipe resistant to high temperatures
0
(100
C).
Testing the electrical system
Switch on the appliance following the instructions for use and cheek the operation of the control devices and plate
heating elements.
Test the various operating temperatures.
If necessary, consult the Troubleshooting guide to identify the problem.
Testing the rated thermal power
Always cheek the thermal power of the appliance after installation and following maintenance work.
The rated thermal power is indicated in the "Technical data" table.
The tank heating elements do not heat up
Check the fuses.
Main power switch not ON.
Low voltage or incorrect electrical connection.
Switch faulty.
Temperature control thermostat faulty.
One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
The temperature control is difficult or impossible to regulate
Temperature control thermostat faulty.
One or more plate heating elements incorrectly connected or burnt out (replace faulty heating element).
IMPORTANT : Before carrying out maintenance work or repairs, disconnect the appliance from the power supply at
the isolating switch.
Thermostat and switch
Remove the upper control panel.
Detach the bulb from the thermostat or switch fixed to the heating element by special support brackets.
Disconnect the electrical connections.
Replace the part.
START UP
TROUBLESHOOTING GUIDE
REPLACEMENT OF SPARE PARTS