TROUBLESHOOTING CON'T
Message
Possible Cause(s)
The AdvanTEXT
The backup batteries
device is chirping
are low
every 30 seconds
All of the lights are
The backup batteries
flashing on and
are too low to power
off and the device
the AdvanTEXT
keeps beeping
device
The alarm is
The dual float switch
going off
is obstructed by
even though the
debris
dual float switch
is not
The input jack
submerged in
connecting to the
water
device is loose
or unplugged
Text messages
Poor signal strength
arrive out of
order
Cellular network
congestion
The AdvanTEXT
The phone number
device is not
was entered
communicating
incorrectly
with my phone
If you have added a phone number in error or you want to change a contact number type
"Phone1{space}none"
If the incorrect number is Phone2 or Phone3 repeat the sequence above for the correct number.
You will receive a confirmation text from your device that the number has been cleared. Repeat Step 7 to enter a new
emergency contact number.
For Replacement Parts or Technical Assistance,
call 1-888-636-6628
Please provide following information:
- Model number
- UNIT ID
- Part description and number as shown in parts list
Address parts correspondence to:
Blue Angel Pumps
101 Production Drive
Harrison, OH 45030 U.S.A.
Ref. No.
Description
Dual Float Sensor
1
with Hose Clamp
2
Tether Float
Corrective Action(s)
Replace the backup batteries. Use only alkaline batteries
Do not use "heavy duty" batteries
Replace the backup batteries. Use only alkaline batteries
Do not use "heavy duty" batteries
Check the dual float switch for debris, clear obstruction and
reset device
Push connector into the device. Pull on connector to verify fully inserted
Locate the AdvanTEXT device to an area with better cellular reception
Contact customer service 1-888-636-6628
No remedy
Double check the phone number entered, as a contact in Step 5.
Make sure you did not put a "1" in front of the area code
Part No.
Quantity
60158-BLU2
1
66347-BLU2
1
1
7
DFA
2
www.blueangelpumps.com