Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Sewage Pump
Description
A sewage system consists of a pump,
control switch, and a ba sin for use in
ap pli ca tions where less than six toilets
(units) are dis charged into the basin.
The sys tem is generally con trolled by a
float switch with a plug-in-plug which
accepts the pump plug and in turn
plugs into a 115 volt outlet.
The float switch is a wide angle
differential switch that rises with the
liquid level and turns the pump on.
As the liquid level decreases the float
lowers and turns the pump off. This
pump is in tend ed for use in do mes tic
sewage lift stations. It is suitable for
pumping sewage, effluent, wastewater,
groundwater and other non ex plo sive,
non cor ro sive liquids with up to 2 inch
solids.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 4/10 (BSEL40); 1/2 (BSEL50)
Motor full load .................................. 12 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
Cut-in level (factory set) .................... 18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
Power cord ......................................... 16 gauge 3 conductor
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2008 Blue Angel™ Pumps
unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
NPT male
mechanical tether switch
w/plug
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
BSEL40, BSEL40M, BSEL40T-2,
BSEL50, BSEL50M
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIfORNIA PROPOSITION 65
Danger indicates
an imminently
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER hOuR AT TOTAL hEAD IN fEET
Model
BSEL40
BSEL50
Warning indicates
a potentially
Caution indicates
a potentially
Notice indicates
important
This product or its
power cord contains
polypropylene
10
15
3700
1350
6420
4200
1500
330004-002 12/08
200
0

Publicité

Table des Matières
loading

Sommaire des Matières pour Blue Angel Pumps BSEL40

  • Page 1 Volute ........Glass reinforced ABS Motor ..........115V, 1 Phase, 1725 RPM Impeller .........Glass reinforced PBT Horsepower ........4/10 (BSEL40); 1/2 (BSEL50) Motor full load ........12 amps Seal plate ......Cast Iron Liquid temperature range ....40º F to 120º F Shaft seal .......End faced mechanical...
  • Page 2 Operating Instructions and Parts Manual General Safety Information 6. Check hoses for weak and worn 11. This equipment is only for use on condition before each use, making 120 volt (single-phase) and is (Continued) certain that all connections are equipped with an ap proved 3-con- GENERAL SAfETy secure.
  • Page 3 BSEL40, BSEL40M, BSEL40T-2, BSEL50, BSEL50M availability. If a check valve is used in a solids in the basin so the impeller remains handling system mount the check submerged. valve in a horizontal position or at General Safety Information When a tether switch is used, rigid a 45º...
  • Page 4: Troubleshooting Chart

    Operating Instructions and Parts Manual Remove all scale and deposits on freely after cleaning. laws before disposing of this oil. This oil can be harmful to aquatic life so pump. Clean all dirt and deposits away consideration should be exercised in the from pump inlet and volute.
  • Page 5: Repair Parts List

    Motor housing gasket 17456-002 Impeller 17317-001 Volute (includes 6 screws) 23272-001 Dielectric oil 55932 2.2 pints Mechanical switch kit (BSEL40, BSEL40M, BSEL50, BSEL50M) 60022-001 Mechanical switch kit (BSEL40T-2) 56836-002 Oil plug 37303-001 #8 - 16 x 1 inch screw 67112-001 www.blueangelpumps.com...
  • Page 6: Service Record

    Operating Instructions and Parts Manual Service Record Date Maintenance performed Repair components required Limited Warranty For one year from the date of purchase, Blue Angel™ Pumps will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or workmanship.
  • Page 7: Pompe Pour Eaux Usées

    Moteur ..........115V, Monophasé, Volute ........ABS renforcé de verre 1725 tr/min Turbine ........PBT renforcé de verre Horse Power ........4/10 (BSEL40) 1/2 (BSEL50) Plaque d’étanchéité .....En fonte Moteur à pleine charge ..... 12 A Joint d’arbre ......Mécanique Gamme de température du liquide .. 4ºC à 49ºC (40º F à 120º F) Position de fonctionnement max.
  • Page 8: Généralités Sur La Sécurité (Suite)

    Instructions d‘Utilisation et Manual de Pièces Généralités Sur La Sécurité 6. Inspecter les tuyaux pour la faiblesse 11. Cet équipement est conçu pour un et l’usure avant chaque utilisation circuit de 120 v (monophasé) et est (Suite) et vérifier le serrage de tous les équipé...
  • Page 9: Entretien

    BSEL40, BSEL40M, BSEL40T-2, BSEL50, BSEL50M Généralités Sur La Sécurité Installation Avant d’enlever la pompe du bassin (Suite) Utiliser un/des pour l’entretien, toujours couper système(s) de Le moteur de la puissance à la pompe et à sauvegarde là où il y a risque de la pompe est l’interrupteur de commande.
  • Page 10: Entretien (Suite)

    Instructions d‘Utilisation et Manual de Pièces Entretien (Suite) montage incorrect peuvent résulter au nettoyage. en hasard de secousse électrique. Enlever le couvercle du bassin Netttoyer toute saleté et dépots de et débrancher la tuyauterie de Situer la pompe dans un endroit l’arrivée de la pompe et la volute.
  • Page 11: Guide De Dépannage (Suite)

    Joint d’étanchéité du carter 17456-002 Turbine 17317-001 Volute (inclus 6 vis) 23272-001 D’huile Diélectrique 55932 2.2 pints Trousse d’interrupteur mécanique (BSEL40, BSEL40M, BSEL50, BSEL50M) 60022-001 Trousse d’interrupteur mécanique (BSEL40T-2) 56836-002 Bouchon d’huile 37303-001 #8 - 16 x 1 po Vis 67112-001 11 fr...
  • Page 12: Enregistrement D'entretien

    Instructions d‘Utilisation et Manual de Pièces Enregistrement d’entretien Date Entretien exécuté Éléments de remplacement requis Garantie Limitée Pour un an à compter de la date d’achat, Blue Angel™ Pumps vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes (“Produit”) déterminées défectueuses, par Blue Angel, en matière ou en fabrication.
  • Page 13 Ciclo del motor ......Intermitente Caja espiral ......Plástico ABS reforzado Motor ........... 115V, 1 fase, 1725 RPM con vidrio Caballos de fuerza ...... 4/10 (BSEL40) 1/2 (BSEL50) Impulsor ........Plástico PBT reforzado Motor (Cap. máx.) ....... 12 amperios con vidrio Temp. de funcionamiento ..4ºC a 49ºC (40º F a 120º F) Sello de la placa ....Hierro colado...
  • Page 14 Manual de Instrucciones de Operación y Piezas Informaciones Generales de Antes de cada uso, inspeccione ¡Peligro las mangueras, para ver si están Seguridad (Continuación) de choque eléctrico! Nunca dañadas o desgastados y cerciórese conecte los cables verdes o GENERALES DE SEGuRIDAD de que las conexiones estén bien verde con rayas amarillas, a apretadas.
  • Page 15 BSEL40, BSEL40M, BSEL40T-2, BSEL50, BSEL50M Informaciones Generales de Mantenimiento Enrosque la tubería de descarga o el niple en el orificio de descarga Seguridad (Continuación) Siempre desconecte de la unidad. 13. Es altamente recomendable que el cordón eléctrico Si usa una válvula de chequeo, en...
  • Page 16: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas Mantenimiento Coloque la bomba en un Limpie bien el orificio de entrada de sitio adecuado para limpiarla la bomba y la voluta. (Continuación) completamente. Quítele todos los Esta bomba Chequée la bomba periódicamente residuos e impurezas a la bomba.
  • Page 17 17317-001 Caja espiral (incluye 6 tornillos) 23272-001 Aceite dieléctrico 55932 2.2 pints Juego de interruptor mecánico (BSEL40, BSEL40M, BSEL50, BSEL50M) 60022-001 Juego de interruptor mecánico (BSEL40T-2) 56836-002 Tapón de aceite 37303-001 Tornillo de #8 - 16 x 25,4 mm (1 inch)
  • Page 18: Registro De Servicios

    Manual de Instrucciones de Operación y Piezas Registro de Servicios fecha Maintenimiento efectuado Componentes de reparación necesarios Garantía Limitada Durante un año a partir de la fecha de compra, Blue Angel reparará o reemplazará, según lo consideren adecuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o representantes autorizados de Blue Angel determinen que están defectuosos debido a problemas de materiales o manufactura.
  • Page 19 BSEL40, BSEL40M, BSEL40T-2, BSEL50, BSEL50M Notes / Notas / Notes...
  • Page 20 Operating Instructions and Parts Manual • Instructions d‘Utilisation et Manual de Pièces • Manual de Instrucciones de Operación y Piezas Notes / Notas / Notes...

Ce manuel est également adapté pour:

Bsel40mBsel40t-2Bsel50Bsel50m

Table des Matières