AdvanTEXT LIGHT BLINKING PATTERNS
Your unit will warn you when there is a problem detected.
Use the chart below to determine your notifications and
light patterns.
Status Light
Green Flashing
Green Blinking
Green Solid
Red Solid
Red Blinking Fast
Low Battery Light
Off
Flashing
Water Sensor
Lights
Off
Toggles On/Off with
audible alarm
TROUBLESHOOTING

Troubleshooting Guide

Message
Possible Cause(s)
Status light is on
Insufficient cellular
solid red
signal strength
The status light
An error has occurred
is flashing red
quickly
The low battery
The batteries are not
light is flashing
installed properly
even though I
replaced the
You are using low
batteries
quality batteries
You did not power off
the AdvanTEXT
device before
replacing the batteries
www.blueangelpumps.com
Sleeping or on battery backup
power
Not ready, attempting to
connect to cellular network
Ready
Cellular signal not present
An error occurred
Batteries normal
Batteries low or critically low
Water not detected
Water detected
Corrective Action(s)
Locate the AdvanTEXT device to an area with better cellular
reception, away from metal objects, or higher elevation
Locate the AdvanTEXT device to an interior wall, away from a wall that is
adjacent to soil
Power off the AdvanTEXT device for 10 seconds and then power it
back on
Ensure the polarity of the batteries are correct. The negative (-) end of the
battery touches the spring in each holder
Use only alkaline batteries. Do not use "heavy duty" batteries
Power off the AdvanTEXT device for 10 seconds and then power it
back on
AdvanTEXT AUDIBLE ALARMS
Your unit will warn you when there is a problem detected.
Use the chart below to determine your audible alarms.
Alert
One Second Beep
One Second Beep
(3) One Second Beeps
1/4 Second Beep Every
30 Seconds
One Second Beep
(2) Chirps
(5) Chirps
(3) 1/4 Second Beeps
Definitions:
Flashing - Light will turn on very briefly and then it turns
off for two seconds
Blinking - Light will toggle On/Off every second
6
Event Type
Water sensor activated
Power on (after activation)
Power on (pre-activation)
Battery low or critically low
Push to test
Successful programming
Cellular service or
transmission error
Incorrect or unsuccessful
programming error