The submersible pump is designed
for indoor home sump applications.
The unit is equipped with an 8-ft
long, 3-prong grounding type power
cord. Motor is oil filled and sealed
for cooler running and designed to
operate under water. A float switch
or solid-state electronic water level
control is provided for automatic pump
operation. This pump is not suitable for
aquatic life.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates an
imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
© 2008 Blue Angel™ Pumps
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property damage! Retain instructions for future
reference.
Submersible
Sump Pump
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
IMPORTANT: Information that requires
special attention.
General Safety Information
CALIFORNIA PROPOSITION 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY
Read these rules and
instructions carefully. Failure
to follow these instuctions
could cause serious bodily
injury and/or property
damage.
pump fl ammable or explosive
fl uids such as gasoline, fuel
oil, kerosene, etc. Do not
use in a fl ammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result
to handle salt water, brine, laundry
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
could occur if used in these application
and will void warranty.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
BWST, BWSF and BWSCAP Series
qualifi ed electrician. Failure to follow
Notice indicates
this warning could result in fatal
important
electrical shock.
has water or moisture on
the fl oor, do not walk on
wet area until all power is
turned off. If the shutoff box is in the
basement, call an electrician. Remove
pump and either repair or replace.
Failure to follow this warning could
This product or
result in fatal electrical shock.
its power cord may
Angel offers Model BSP15 and BSP25.
Assembly
VERTICAL FLOAT SWITCH (BWSF
ONLY)
MANUAL
Place the float bracket onto the handle
of the motor housing and slide the
switch assembly securely into place.
Do not
use to
This pump is
not designed
Figure 1
All wiring must be
performed by a
If the
basement
A backup system
should be used. Blue
Switch housing
Float
bracket
Float
350704-002 9/08

Publicité

loading

Sommaire des Matières pour Blue Angel Pumps BWST Serie

  • Page 1 BWST, BWSF and BWSCAP Series Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2 Operating Instructions and Parts Manual Installation cord and replace damaged cords plug. Insert the float switch cord immediately. plug directly into a 120 volt outlet. 1. Install pump in a sump pit with IMPORTANT: Make sure there is 3. Insert the pump power cord plug minimum size as shown in Figure 2.
  • Page 3 BWST, BWSF and BWSCAP Series specifications for cut-in/out levels. Maintenance The pump will recycle thereafter as Always required. disconnect the electrical supply before 5. Do not operate the pump unless it attempting to install, service, is submerged in water. Dry running Working relocate or perform any causes pump failure.
  • Page 4 Operating Instructions and Parts Manual For Replacement Parts or Technical Assistance, Call 1-888-636-6628 Please provide following information: Address any correspondence to: - Model number Blue Angel - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Page 5 BWST, BWSF and BWSCAP Series Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse 1. If blown, replace with proper sized fuse or reset breaker 2. Low line voltage 2. If voltage is under 108 volts, check wiring size 3.
  • Page 6 Operating Instructions and Parts Manual L imited Warranty For one year for BWST and BWSF models and for two years for BWSCAP models from the date of purchase, Blue Angel will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or workmanship.
  • Page 7 Séries BWST, BWSF et BWSCAP Instructions d’Utilisation et Manual de Pièces Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit. Protégez-vous et les autres en observant toutes les informations sur la sécurité.
  • Page 8 Instructions d’utilisation et manual de pièces Installation contre les objets pointus, surfaces 2. Cette pompe est fabriquée pour le chaudes, l’huile et les produits service de 120 volts (monophasé), 60 1. Installer la pompe dans une fosse de chimiques. Éviter le tortillement du hz, 15 A seulement et est équipée taille minumum indiquée ci-dessous.
  • Page 9 Séries BWST, BWSF et BWSCAP Fonctionnement (Suite) Entretien 4. Remplir le puisard d’eau. La pompe Toujours débrancher la source se démarrera automatiquement une d’électricité avant d’essayer fois que l’eau atteint le niveau d’eau La surface d’installer, de déplacer ou de de démarrage et s’arrêtera quand de travail procéder à...
  • Page 10 Instructions d’utilisation et manual de pièces Pour pièces de rechange ou assistance technique, appeler 1-888-636-6628 S’il vous plaît fournir l’information suivante: Adresser toute correspondance à : - Numéro de Modèle Blue Angel - Numéro de série (si présent) 101 Production Drive - Description et numéro de la pièce Harrison, OH 45030 U.S.A.
  • Page 11 Séries BWST, BWSF et BWSCAP Guia Geral de Solução de Problemas Problema Possíveis causas Ação corretiva La pompe ne se démarre pas 1. Fusible sauté 1. Si sauté, le remplacer avec un fusible de et ne fonctionne pas taille correcte ou rajuster le disjoncteur 2.
  • Page 12 Instructions d’utilisation et manual de pièces Garantie Limitée Pendant un an pour les modèles BWST et BWSF, et pendant deux ans pour les modèles BWSCAP, à partir de la date d’achat, Blue Angel vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes (“Produit”) déterminées défectueuses, par Blue Angel, en matière ou en fabrication.
  • Page 13 Series BWST, BWSF y BWSCAP Manual de Instrucciones de Operación y Lista de Partes Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí descrito. Protéjase usted mismo y a los demás observando toda la información de seguridad.
  • Page 14 Manual de Instrucciones de Operación y Lista de Partes Instalación 4. Conéctele una tubería rígida de bomba, el motor, el agua o la tubería de descarga mientras el cordón eléctrico 3,18 cm (1-1/4”) a la pieza de goma 1. Instale le bomba dentro del foso esté...
  • Page 15 Series BWST, BWSF y BWSCAP Funcionamiento (Continued) y el flujo de agua en el pozo de Esta bomba contiene aceite sumidero. dieléctrico para enfriarla. Este aceite 12. Bajo condiciones de inundación, la posterior del enchufe del cordón del puede contaminar el medio ambiente. bomba se apaga por 1 segundo cada Cerciórese de que no está...
  • Page 16 Manual de Instrucciones de Operación y Lista de Partes Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio Sirvase darnos la siguiente información: Dirija toda la correspondencia a: - Número del modelo Blue Angel - Código impreso 101 Production Drive - Descripción y número del repuesto según la lista...
  • Page 17 Series BWST, BWSF y BWSCAP Tabla de Identificación de Problemas Síntoma Causa(s) Posible(s) Medida Correctiva La bomba no se enciende o 1. El fusible está quemado 1. Si se quemó, reemplácelo con un fusible no funciona adecuado o conecte el cortacircuito 2.
  • Page 18 Manual de Instrucciones de Operación y Lista de Partes Garantía Limitada Por un año para los modelos BWST y BWSF y por dos años para los modelos BWSCAP a partir de la fecha de compra, Blue Angel reparará o reemplazará, según lo consideren adecuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o representantes autorizados de Blue Angel determinen que están defectuosos debido a problemas de materiales o manufactura.
  • Page 19 BWST, BWSF, BWSCAP Notes/Notas...
  • Page 20 Operating Instructions and Parts Manual Manual de Instrucciones de Operación y Lista de Partes Manuel d’utilisation et de pièces détachées Notes/Notas...