Switching on
Operation is done with the ON/OFF-switch on the front side of the inverter. In switch-mode ON the
LED control "Power" illuminates.
Malfunctions
150/300 W
If the battery voltage falls below 10.7 V (12V models) or 21.4 V (24 V models) the LED turns orange.
This will also happen when the inverter is overheating.
The inverter switches off automatically in case the battery voltage goes down to 10 V (for 12 V models)
or 20 V (for 24 V models).
1. If this happens, switch off the inverter.
2. Ensure that the inverter is sufficiently ventilated.
3. Wait for approximately 5 - 10 minutes and switch on the inverter only.
600/1000/2000 W
If the battery voltage falls below 10.7 V (12 V models) or 21.4 V (24 V models) the LED control "OVER-
LOAD" illuminates and an audible signal is given. The inverter switches off automatically in case the
battery voltage goes down to 10 V (for 12 V models) or 20 V (for 24 V models).
If the device overheats, the inverter switches off – the "OVER TEMP" LED lights up.
1. If this happens, switch off the inverter.
2. Ensure that the inverter is sufficiently ventilated.
3. Wait for approximately 5 - 10 minutes and switch on the inverter only.
When operating the inverter at a high load for lengthy periods, you have to pay attention to the voltage
of the battery. If the voltage is not enough, please charge the battery immediately or replace it.
There is a modular jack for remote controls for 1500 W and 2000 W on the front panel and for 600 W
(optional) and 1000 W on the bottom plate.
Specifications:
Rated input voltage
Constant output power
Peak output power
Maximum input current
Output voltage
Output frequency
Output wave form
Total harmonic distortion
No load current
Input voltage range
Low voltage alarm
Low voltage shutdown
Efficiency up to
Dimensions (L x W x H)
Weight
Remote controller
GFCI
Safety certification
EMC
Pure sine 150W series
12 V DC
20A
<0.8A
10.5V ~ 16.5V
10.5V
10 V
215 x 147 x 66 mm
EN55022: Class B
EN55024:
EN61000-3-2:
EN61000-3-3:
5
24 V DC
150W
300W
10A
230V AC +/- 3%
50 Hz
Pure sine wave
3%
<0.6A
21V ~ 33V
21V
20 V
85%
1.28Kgs
EN60950-1: