Zivan MG 9 Manuel D'utilisation page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Alarms
When an alarm situation stopping the charge occurs, the display shows one of the information below according failure detected:
The table below describe the alarm list.
Display code
1
LOGIC FAILURE #1
2
3
5
6
7
8
HIGH TEMPERATURE
9
MISMATCH VOLTAGE
10
11
OVER DISCHARGE
12
DEEP DISCHARGE
13
CONNECTION FAULT
14
15
16
LOGIC FAILURE #2
17
FLASH CHECKSUM
18
21
LOGIC FAILURE #3
29
CLOCK BATTERY OFF
30
Notes:
A05:
The charge restarts once the battery temperature reaches a value lower than 50° C.
A11:
Notice on the battery status. By pressing the MODE button, a desulphation phase start followed then by the standard charge.
A12:
Notice on the battery status. The standard charge is starting anyway
A15:
With the thermal sensor out of order the battery charger behaves as if it was not equipped with the external probe
Each temporary alarm, restarts the charge after alarm conditions disappear.
Each alarm, except the non-blocking ones, give also an audible alarm.
This device is in conformity with the Low Voltage directive 2014/35/EU and EMC
directive 2014/30/EU and their further modifications.
D02014-02
MG 9/18/27/36 Battery Charger
<A> <alarm code identified with a 2 digits code>
Alarm Type
CAN BUS KO
WATCHDOG
HIGH BATTERY
TEMPERATURE
MISSING PHASE
OVERCURRENT
TIMEOUT
PUMP MISTAKE
TH. SENSOR KO
EEPROM KO
NODE RESET
Charge stop
Trouble on current circuit (turn off/on the charger. If the
Yes
problem persists please contact customer service).
Trouble on CAN communication (verify CANBUS
No
communication).
Logic board trouble (turn off/on the charger. If the problem
Yes
persists please contact customer service).
Battery temperature over than 55° C (the charger restarts when
Temporary
battery temperature goes under 50° C).
One of the three input phase cannot be detected by the
Temporary
charger (check for all three phases to be connected to the
charger, or contact customer service) .
Anomalous input current absorption (charger restarts after 3
Temporary
seconds. If the problem persists please contact customer
service).
Internal high temperature (turn off/on the charger. If the
Yes
problem persists please contact customer service).
Trouble on voltage circuit (turn off/on the charger. If the
Yes
problem persists please contact customer service).
End of Phase 1 due to timeout (check if charger is suitable for
Temporary
the specified battery type – disconnect the battery).
No
Over discharged battery
No
Deeply discharged battery.
Connection fault in the output cables. Disconnect the battery
Temporary
and wait for the display to show three dots before connecting a
new battery.
No
Air pump mis-working
No
Thermal sensor failure.
Voltage sag (charger restarts after 3 seconds. If the problem
Temporary
persists please contact customer service).
Error in flash memory (turn off/on the charger. If the problem
Yes
persists please contact customer service)
Problem in EEPROM communication (turn off/on the charger.
Yes
If the problem persists please contact customer service).
The output voltage has exceed a safety threshold (turn off/on
Yes
the charger. If the problem persists please contact customer
service).
No
The Clock battery is discharged or removed
The CAN Node has been set to 126, which is the reset value.
Yes
The charger forces you to enter again the Changing settings
(see the charging curve selection section)