Replacing the mains line
of the pump must be performed by a
trained technician
1. Loosen shell screws (2 screws).
2. Unscrew strain relief device.
3. Loosen mains connection clamp on
the switch and protective wire
connection screw on the motor shell.
4. Thread new mains cable (line type
H07 RN- F3G 1.0 or 1.5) with
prepared ends through the socket
and secure with strain relief clamp
from becoming disconnected.
5. It is absolutely necessary that the
protective conductor should be sub-
stantially longer than both the other
conductors. Should the mains cable
be accidentally pulled out, the pro-
tective conductor must be the last
which is pulled free from the clamp.
6. Manually check the clamp and strain
relief device.
7. Reassemble the shell halves.
8. Perform a trial run.
Spare parts ordering
instructions
If you should requiring spare parts for
your pump at a later time, we request
you to give the following information
when ordering:
1. Pump type
2. Identification number
3. Amount
4. Positions number
5. Designation of spare part
6. Spare part number
13.11.2001 15:13 Uhr
Disturbances
1. Motor does not run
Causes
– Mains voltage missing
– Pump wheel blocked – thermal
guards has shut off
2. Not pump intake
Causes
– Suction valve not in water
– Pump champer is without water
– There is air in the suction line
– Suction valve leaks
– Suction basket (suction valve) is
blocked
– Max. intake height execeeded
3. Transport volume insufficient
Causes
– Intake height too hight
– Suction basket contaminated
– Water level quickly drops
– Pump performance reduced
becaus of contaminants
4. Thermal pump switches pump off
Causes
– Motor overloaded, friction from
foreign material too high
ATTENTION!
The pump must not be allowed to run dry.

Technical data:

Mains connection:
Capacity:
Alternating current, asynchronous motor rotation:
Transport height:
Transport volume max.:
Transport pressure max.:
Intake height max.:
Water temperature max.:
Suction and pressure connection internal screw thread
Seite 7
Remedy
– Check voltage
– Disassemble pump and clean
Remedy
– Place suction valve in water
– Put water into intake connection
– check for leakage in suction line
– Clean suction valve
– Clean suction basket
– Check intake height
Remedy
– Check intake height
– Clean suction basket
– Place suction valve lower
– Clean pump and replace worn
out parts
Remedy
– Disassemble pump and clean,
prevent intake of foreign
materials
GB
230 V ~ 50 Hz
800 Watt
2850 U/min.
40 m
2600 l/h
4 bar
8 m
40° C
R 1"