Function settings
5
44
Change the settings with the
•
Temp. range: No (unrestricted) or Yes (restricted)
•
Upper and lower limit temperature (1ºC increments)
•
Heat: Upper and lower limit temperature (1ºC increments)
•
Auto: Upper and lower limit temperature (1ºC increments)
Temperature setting ranges
Mode
*1
*3
*2
Heat
*3
Auto
*4
* The settable range varies depending on the connected unit.
*1 Temperature ranges for the Cool, Drying, and Auto (dual set
point) modes can be set.
*2 Temperature ranges for the Heat and Auto (dual set point) modes
can be set.
*3 Temperature ranges for the Heat, Cool, and Drying modes must
meet the conditions below:
temperature difference (varies with indoor unit model)
temperature difference (varies with indoor unit model)
*4 Temperature range for the Auto (single set point) mode can be
set.
Press the
button to save the settings.
SELECT
A confirmation screen will appear.
Navigating through the screens
To go back to the Main menu ..........
To return to the previous screen ......
will appear on the Status display and the Main
display in the Full mode when the temperature range
is restricted.
or
button.
F3
F4
Lower limit
Upper limit
19 ~ 30ºC
30 ~ 19ºC
(67 ~ 87ºF)
(87 ~ 67ºF)
17 ~ 28ºC
28 ~ 17ºC
(63 ~ 83ºF)
(83 ~ 63ºF)
19 ~ 28ºC
28 ~ 19ºC
(67 ~ 83ºF)
(83 ~ 67ºF)
MENU
button
button
RETURN