Maintenance And Storage - Master MH-16-TTC Manuel De L'utilisateur Et Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Lighting Instructions (cont.)
9. Once lit, keep the plunger depressed for thirty
(30) seconds. Then release the plunger, and if
the burner stays lit, remove and extinguish the
match. You will know that the burner is lit when
the mesh screen begins to glow red.
10. If the burner does not stay lit, repeat the
lighting process. If the heater does not light
after several attempts, be sure you are getting
fuel to the burner. The faint smell of gas will tell
you if the fuel is flowing. If not, there may be a
problem with your LP cylinder. Take it back to
your local dealer for replacement.
11. Once the burner is lit, turn Regulator Control
Knob to desired setting (HI) / (MED) / (LO ).
12. Light all burners when maximum heat is
desired. Follow Lighting Instructions steps
1-11. The second and third burner should be
lit separately. Do Not Attempt to light second
burner off the first burner. Be sure NOT to
point burners at one another.
1. Inspect your heater before each use. Check all
connections for leaks, following the procedure
outlined on Page 9. Check the Regulator Hose
(dual burner models only) for any cracks,
breaks or wear. If the hose is damaged replace
it with the correct manufacturers part. Heater
should be inspected before each use and
once annually by a qualified service person.
© 2018 Pinnacle Climate Technologies, Inc.
WHILE BURNING OR WHILE CONNECTED
OPERATION (CONT.)

MAINTENANCE AND STORAGE

NEVER LEAVE HEATER UNATTENDED
TO A FUEL SOURCE
To Turn Off Heater:
1. Turn the valve on the LP cylinder CLOCKWISE to
stop the flow of fuel.
2. Turn the heater regulator knob to the
position and wait at least fifteen (15) minutes for
the heater to cool.
3. Tightly close the gas shutoff valve on the LP
cylinder after each use.
4. Remove the heater from the LP cylinder by
reversing the steps in Connecting Heater to
LP Cylinder on Page 9. DO NOT store the LP
cylinder with the heater still attached or in an
enclosed area.
NOTE: ALWAYS INSPECT HEATER BEFORE USE
AND AT LEAST ANNUALLY BY A QUALIFIED
SERVICE PERSON.
EXTREMELY HOT during
DANGER
operation. Do Not touch any
metal components while in operation. Keep
gasoline and any other flammable liquids
away from the heater.
Never bring or store a propane
DANGER
cylinder indoors.
DO NOT insert the lit match
CAUTION
into the air inlet holes in the
mixing tube.
2. After use, always disconnect the heater
from the LP cylinder, and store the heater
separately from the tank. Be sure to close
the tank valve after use, and before storage.
The LP cylinder should be stored outdoors in
accordance with chapter 5 of the Standard for
Storage and Handling of Liquefied Petroleum
Gases (ANSI/INFPA 58).
Propane Tank Top Heater User's Manual
12
(OFF)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-32-ttcMh-47-ttc

Table des Matières