Master MH-16-TTC Manuel De L'utilisateur Et Instructions D'utilisation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MH-47-TTC (Continued):
– To have all 3 burners face front, the plane
washer should be to the right side of tank collar
bracket (see Figure 3).
Figure 3
Connecting Heater to LP Cylinder:
Be sure to read and understand all of the Safety
Information in this manual before connecting
the heater to the LP cylinder. Installation must
conform to local codes and with the Standard for
the Storage and Handling of Liquefied Petroleum
Gasses and ANSI/NFPA 58.
Inspect the hose and regulator prior to each
use of the heater. If there is excessive abrasion
or wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list prior to
using the heater.
Model MH-16-TTC:
1. Be sure that the control knob on the regulator is
in the "OFF" position.
2. Line up the threads on the fuel connector nut
with the threads on the LP cylinder valve. Turn
fuel connector nut COUNTERCLOCKWISE to
tighten. Fully tighten the nut, being careful not to
over tighten.
3. Slowly open the LP cylinder valve.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING OR WHILE CONNECTED
TO A FUEL SOURCE
ASSEMBLY
– To have far left burner face back, the plane
washer should be to the left side of tank collar
bracket (see Figure 3).
Models MH-32-TTC / MH-47-TTC:
1. Be sure that the control knob on the regulator is
in the "OFF" position.
2. Line up the slots in the tank collar bracket with
the tank collar ring and slide into place. Be
sure the mounting knob is to the outside, and
tighten.
3. Line up the threads on the fuel connector nut
with the threads on the LP cylinder valve. Turn
fuel connector nut COUNTERCLOCKWISE to
tighten. Fully tighten the nut, being careful not to
over tighten.
4. Slowly open the LP cylinder valve.
Check all connections for leaks using a 50/50
mixture of dish-soap and water. Any bubbles
that appear show a leak. Remove and reconnect
the Connector Nut to the valve.
WARNING
cylinder located within 20 feet of the heater.
Propane Tank Top Heater User's Manual
9
DO NOT direct the heater dis-
charge towards any propane

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-32-ttcMh-47-ttc

Table des Matières