NOCO Genius BOOSTMAX GB500 Guide D'utilisation Et Garantie page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
EN
1 . Internal Battery Level Indicates the charge level of the internal battery.
2 . Hot LED Illuminates solid Red; unit is fully operational, but approaching upper temperature limit.
Flashing Red; unit is too hot to jump start, but other functions are still available.
3 . Cold LED Illuminates solid Blue; unit is fully operational, but approaching lower temperature limit.
Flashing Blue; unit is too cold to jump start, but other functions are still available.
4 . Error LED Illuminates Red, if reverse polarity is detected.
5 . Voltage Indicator Indicates the battery system voltage the GB500 is currently set to. 12V illuminates White when in 12V
mode, 24V illuminates Blue when in 24V mode.
6 . Power Button Push to turn unit "On" and "Off".
7 . Power LED Illunimates White when unit is "On".
8 . Voltmeter The built-in voltmeter reads the voltage of the vehicle's battery for enhanced diagnostics and troubleshooting.
The voltmeter will automatically read the voltage of any battery (or battery system) when the battery clamps are connected
- even if the unit is powered off. The voltmeter will read voltage between ~3V to ~30V. If the connected battery is below 3V,
nothing will display. In this situation, it is likely there is a load(s) on the battery, such as, headlights or an AC fan that should be
shut off before attempting to start the vehicle.
9 . Boost LED Illuminates White when Boost is active. If the unit is connected properly to a battery, the GB500 will
automatically detect a battery and go into Boost mode (White LED flashes when Manual Overide feature is active).
10 . Manual Override LED Illuminates solid Red when Manual Override is activated.
11 . Manual Override Button To enable, push and hold for three (3) seconds. WARNING: Disables safety protection
and manually forces Boost "On". Only for use when a battery is too low to be detected.
12 . Voltage Selection Knob Turn to switch between 12V and 24V mode.
13 . Light Mode Button Toggles the worklight through 7 light modes: 100% > 50% > 10% > SOS > Blink > Strobe > Off.
14 . USB Out LED Illuminates White; USB Out function can be used in both 12V and 24V modes.
15 . 12V Out LED Illuminates White; 12V Out function can only be used in 12V mode.
16 . 12V In LED Illuminates White; 12V In function can only be used in 12V mode.
17 . Light Mode LED Illuminates White when the worklight is turned "On", but the unit is off.

Publicité

Table des Matières
loading

Table des Matières