Installation
1

Install Unit

Rough-in of plumbing lines and wall braces must be
completed before unit can be properly installed.
Remove Access panel and with
A
the help of another person, place
unit in position against wall.
B
Ensure unit is level, shimming fl oor unit if
necessary. Mark the wall anchor locations.
2
Connect Water Supply to Valve Assembly
Connect 1/2" NPT female end of stop/check
A
valves to supply lines. Connect supply hoses
to hot and cold inlets of the Vernatherm TMV.
Do not turn on water until Step 4 is completed!
Bradley Corporation • 215-1073 Rev. H ; EN 10-00-015
Water Supply Gang
Valve Assembly
Vernatherm TMV
OPTIONAL TEMPERED LINE CONNECTION: Connect 1/2"
B
NPT female end of stop/check valve to supply line. Connect
Tempered line adapter to Gang Valve Assembly as shown.
C
Red Tube
(to Aerator)
Green Tube
(to Aerator)
Black Tube
(to Aerator)
Cold Supply Inlet
Hot Supply Inlet
SN2003/IR, SN2023/IR
Install suitable wall anchors (supplied
by installer) for 3/8" bolts at the marked
locations. Secure unit to wall.
Water Supply Gang
Valve Assembly
OPTIONAL Tempered Line Adapter
Assembly (S39-685)
Braided
Hose
Stop/Check Valve
7-12-2010
5