7. Possible Malfunctions

In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Malfunction
No cooling
Insufficient
cooling capacity
Cause
• Improperly connected
power cord
• Electrical circuit safety
fuse has gone off
• Power outage
• Damaged temperature
controller
• Device is too close to
source heat or direct
sunlight
• Poor air circulation in the
device
• The device is overfilled
• Stored food is too warm
• Improperly closed door
or the door was left
open too long
• Improper temperature
setting
:
Solution
• Pull the plug and reinsert it
into the socket correctly
• Check the fuse, check the
device by connecting it to
another socket
• Check the power source
• Contact the sales agent
• Ensure sufficient distance
between the device and
heat sources
• Ensure sufficient distance
from walls and other objects
• Remove excess food
products
• Cool down the food products
before storing them in the
device
• Close the door and shorten
the time of its opening
• Set lower temperature
- 39 -