RIKA DOMO PGI MULTIAIR Notice De Montage page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Run the fan cable and the cable of the flame sensor further through
the two recesses at the heat deflectors and further to the vertical
cable shaft.
Note
All cables must be protected from heat. Improper installation can
damage your stove and void your warranty.
Loosen the nut and the ring from the capacitor till the end from the
thread.
Attach the condenser in the free slots behind the cable channel.
In the cable channel is the three pin connector M3 for the convection
fan. Insert the correct cable and put all cables and plugs back into
the cable channel.
Before mounting the rear panel, pass the flame sensor cable and the
fan cable through the recess provided for that purpose in the rear
panel. Mount the cable cover.
Install the rear wall of the stove. The fan motor must be covered with
the motor cover. This is only hanged in.
Note
Operation without a cover is not allowed for security reasons.
Disregard voids your warranty and no liability is accepted for
damage.
Function test and settings
Connect the power cord back in and select the Setup menu /
submenu Service. Perform a relais test to check the correct function
of the Multi Air fan.
#13
Select the Setup menu /submenu MULTIAIR fan. Switch the
MULTIAIR 1 to ON and you will get access to fan speed and fan
adaptation.
Fan level
The volume of convection air is adjustable from AUTO (adapts
automatically according to heating power), over to Level 1 (min) and
level 5 (max).
Fan area
In addition, it is possible to adapt the Multi Air fan speed (AUTO, level
#13
1 to level 5) within +/- 30% of fan speed.
#25
#25
|27
26

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Domo

Table des Matières