3. INSTALLATION AND CONNECTION
within sight of and readily accessible from the unit. This is common practice on commercial and
residential air conditioners and heat pumps. It prevents remotely-energizing unattended equipment
and permits turning off power at the unit while the unit is being serviced.

3.6 Initial startup of the Unit

NOTE- In order for the unit to heat the pool or spa, the filter pump must be running to circulate
water through the heat exchanger.
Start up Procedure - After installation is completed, you should follow these steps:
1. Turn on your filter pump. Check for water leaks and verify flow to and from the pool.
2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire controller. It
should start in several seconds.
3. After running a few minutes make sure the air leaving the top(side) of the unit is cooler
(Between 5-10℃)
4. During the operation of the unit, if the filter pump turns off, the unit should also turn off
automatically.
5. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is
reached. When the water-in temperature reaches this setting, the unit will slow down for a period
of time, if the temperature is maintained for 45 minutes the unit will turn off. The unit will now
automatically restart (as long as your pool pump is running) when the pool temperature drops
more than 0.2 below set temperature.
Time Delay- The unit is equipped with a 3minute built-in solid state restart delay included to
protect control circuit components and to eliminate restart cycling and contactor chatter. This time
delay will automatically restart the unit approximately 3 minutes after each control circuit
interruption. Even a brief power interruption will activate the solid state 3minute restart delay and
prevent the unit from starting until the 5minute countdown is completed.