Example: For an output resolution of 300 dpi, take the true resolution
shown in Table 1, divide by 300 dpi and multiply by 100%. Enter the
result in the Zoom Þeld in the main ColorFlex window.
Original
Max Resolution
24x36
5760
-----------
300
= 1920%
36x24
1067%
60x60
1067%
60x90
1067%
60x120
1067%
4Ó x 5Ó
600%
A4
320%
Table 2: Zoom settings for true optical resolution at 300 dpi output
Note that when the Zoom Þeld is set to an appropriate value for the
selected original size (as shown in the table above), then the DPI pop-
up menu shows an underline beneath each setting that will result in a
scan taken with a true resolution (no interpolation).
Imacon Flextight Precision II UserÕs Guide
Hardware ReferenceÑFlextight Precision II
Zoom Setting
1/2
Res.
960%
640%
´
100%
533%
356%
533%
356%
533%
356%
533%
356%
300%
200%
180%
107%
True Optical Resolutions
1/3
1/4
1/6
Res.
Res.
Res.
480%
320%
266%
178%
266%
178%
266%
178%
266%
178%
150%
100%
80%
53%
17
1/12
Res.
160%
89%
89%
89%
89%
50%
27%