6) Connect Electrical Supply
7) Final Check
Before Calling Service
Product Data Plate
•
The appliance must be isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
Before connecting 5-foot (1.5 m) supply cord to wall receptacle, make certain that
gas shutoff valve and all burner controls are in OFF position.
After electrical connection is complete, place each burner cap in correct sized
notched position and check operation of electric igniters. Check flame characteris-
tics. Flame should be blue with no yellow tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that the regulator is set for
the correct fuel. After adjustment, retest.
Some yellow streaking is normal during the initial start-up. Allow unit to oper-
If the elements do not heat or if the indicator "on" light does not glow, check the
power source to see if a fuse has blown or if the circuit breaker has tripped.
Refer to the Warranty in the Use and Care Manual. See Use and Care manual for
troubleshooting information.
The data plate shows the model and serial number of your cooktop. It is located in
the center front area of the rough-in box, underneath the cooktop.
Keep your invoice or escrow papers for warranty validation if service is needed.
English 7