Countertop Requirements

1/8" (3.5mm)
Min Clearance
from Cooktop to
Start of Radius
Gas Requirements -
Supply Pressure
Propane Gas Installation
(NGT Models only)
English 4
Figure 2 - Cutout Dimensions
1-3/4" (44.5 mm) Min. to
Combustible Wall
6" (152.4mm) Min
to Left Side Wall
2 1/4" (57.2mm)
Min. to Counter
7-3/8"(187.8 mm)
Front
Min. to
Table 1: Cutout Dimensions
Fig. 2
A - Cutout
B - Cutout
C - Corner
D - Overall
Natural Gas - 6 inches water column (14.9 Millibars) minimum.
Propane Gas -11 inches water column (27.4 Millibars) minimum.
NOTE: NGP models cannot be converted for propane use.
The propane gas tank must be equipped with its own high pressure regulator in
addition to the pressure regulator supplied with this unit. The cooktop is shipped
from the factory for use with natural gas. For use with LP, a conversion kit is
required and must be purchased separately. Contact BSH or your retailer to obtain
kit # NEZ1065. A qualified technician or installer must do the conversion.
Leak testing of the appliance shall be conducted according to manufacturerís
instructions.
3" (76.2 mm) Min. to
Right Side Wall
3" (76.2 mm) Min.
to Back Wall
Left Side Wall
30" Models
19-1/8" to 19-7/8"
(486.1mm) to
(505.6mm)
28-5/8" to 29-3/8"
(727.2mm) to
(746.6mm)
30" (762mm)
31" (787.4mm)
21" (533.4 mm) cooktop depth
4" (101.6mm) Below Countertop
36" Models
19-1/8 to 19-7/8"
(486.1mm) to
(505.6mm)
34-5/8" to 35-5/8"
(879.6mm) to (899mm)
36" (914.4mm)
37" (939.8mm)
4 3/8" (111.6mm)
Min. to Right
Side Wall