Evco S.p.A. • Code 104X201E314 • page 6/8
d17
1
1 0
- - - -
not avail.
d18
0
3,000 min
not avail.
d19
0.0
40.0
°C/°F (1)
not avail.
d20
0
500
min
not avail.
d21
0
500
min
not avail.
d22
0.0
10.0
°C/°F (1)
not avail.
°C/°F (1)
d23
0.0
10.0
not avail.
PAR.
MIN.
MAX.
UM
EVX201
A0
0
1
- - - -
not avail.
A1
-99.0
99.0
°C/°F (1)
-10.0
A2
0
2
- - - -
1
°C/°F (1)
A4
-99.0
99.0
10.0
A5
0
2
- - - -
1
A6
0
240
min
120
A7
0
240
min
1 5
A8
0
240
min
1 5
A9
0
240
min
1 5
A10
0
240
min
not avail. not avail. not avail.
A11
0.1
15.0
°C/°F (1)
2.0
A12
0
2
- - - -
not avail. not avail. not avail.
PAR.
MIN.
MAX.
UM
EVX201
F0
0
5
- - - -
not avail.
F1
-99.0
99.0
°C/°F (1)
not avail.
F2
0
2
- - - -
not avail.
F3
0
1 5
min
not avail.
F4
0
240
sec
not avail.
F5
0
240
sec
not avail.
F6
0
1
- - - -
not avail.
°C/°F (1)
F7
-99.0
99.0
not avail.
F8
0.1
15.0
°C/°F (1)
not avail.
F9
0
240
sec
not avail. not avail.
F11
0.0
99.0
°C/°F (1)
not avail. not avail.
F12
0
240
sec
not avail. not avail.
F13
0
240
min
not avail.
F14
0
240
min
not avail.
PAR.
MIN.
MAX.
U M
EVX201
i 0
0
5
- - - -
1
i 1
0
1
- - - -
0
i 2
-1
120
min
3 0
1
1
1
number of evaporator temperature values used for the calculation of the relative average (for the defrost activation; only if d8 = 3); also look
at r7, i11 and i12
4 0
4 0
4 0
defrosting interval (only if d8 = 3 and for condition 1)
0 = defrosting for condition 1 will never be activated
3.0
3.0
3.0
evaporator temperature above which the defrost is activated (relative to the evaporator temperatures average, or "evaporator temperatures
average - d19") (only if d8 = 3 and for condition 2); also look at d17
180
180
180
minimum consecutive time the compressor must be switched on such as to provoke the defrost activation
0 = the defrost will never be activated because the compressor has been switched on
200
200
200
minimum consecutive time the compressor must be switched on after the insturment switches on (on condition that the difference "cell
temperature - working setpoint" is higher temperature r7) and after function Overcooling is activated such as to provoke the defrost
activation
0 = the defrost will never be activated because the compressor has been switched on
2.0
2.0
2.0
evaporator temperature above which the defrosting interval is suspended (relative to the evaporator temperatures average, or "evaporator
temperatures average + d22") (only if d8 = 3 and for condition 1); also look at d17
1.0
1.0
1.0
evaporator temperatures average increase during function Energy Saving (for defrost activation; only if d8 = 3); also look at d17
EVX203 EVX204/5 EVX214/5
TEMPERATURE ALARMS
0
0
0
temperature associated with the minimum temperature alarm (code "AL")
0 = cell temperature
1 = evaporator temperature (12)
-10.0
-10.0
-10.0
temperature below that at which the minimum temperature alarm is activated (code "AL"); see also A0, A2 and A11
1
1
1
type of minimum temperature alarm (code "AL")
0 = alarm absent
1 = relative to working setpoint (that is "working setpoint - A1"; consider A1 without sign)
2 = absolute (that is A1)
10.0
10.0
10.0
temperature higher than that at which the maximum temperature alarm is activated (code "AH"); see also A5 and A11
1
1
1
type of maximum temperature alarm (code "AH")
0 = alarm absent
1 = relative to working setpoint (that is "working setpoint + A4"; consider A1 without sign))
2 = absolute (that is A4)
120
120
120
delay in maximum temperature alarm (code "AH") after the instrument is switched on (3)
1 5
1 5
1 5
temperature alarm delay (code "AL" and code "AH")
1 5
1 5
1 5
delay in maximum temperature alarm (code "AH") following the conclusion of defrosting (in EVX201 only) and following the conclusion
of evaporator fan (in EVX203, EVX204, EVX214, EVX205 and EVX215 only) (13)
1 5
1 5
1 5
delay in maximum temperature alarm (code "AH") following the disactivation of the door microswitch input (14)
1
duration of interruption in the power supply that occurs when the instrument has been running for long enough to cause the storage of
the power interruption alarm when the power supply is restored. (code "PF") (15)
2.0
2.0
2.0
differential of parameters A1and A4
1
kind of signal for power interruption alarm (code "PF"); also look at A10
0 = the alarm will not be signalled
1 = the display will show the code "PF" flashing and the buzzer will be activated
2 = the display will show the code "PF" flashing and the buzzer will be activated (this last on condition that the power interruption duration
is higher than time A10)
EVX203 EVX204/5 EVX214/5
EVAPORTOR FAN
1
1
1
evaporator fan activity during normal operation
0 = switched off
1 = switched on; see also F13, F14 and i10
2 = in parallel with the compressor; see also F9, F13, F14 and i10
3 = dependent on F1 (16)
4 = switched off if the compressor is switched off, dependent on F1 if the compressor is switched on; see also F9 (16)
5 = dependent on F6; see also F9
-1.0
-1.0
-1.0
evaporator temperature above the limit at which the evaporator fan is switched off (only if F0 = 3 or 4); see also F8
0
0
0
evaporator fan activity during defrosting and dripping
0 = switched off
1 = switched on (setting parameter d7 to 0 is recommended)
2 = dependent on F0
2
2
2
maximum duration of evaporator fan disactivation; see also F7 (during evaporator fan desactivation the compressor can be switched on,
the defrosting output will remain disactivated and the evaporator fan will remain switched off)
6 0
6 0
6 0
time duration that evaporator fan is switched off during operation for a low percentage of relative humidity when the compressor is
switched off; see also F5 (only if F0 = 5)
1 0
1 0
1 0
time duration that evaporator fan is switched on during operation for a low percentage of relative humidity when the compressor is
switched off; see also F4 (only if F0 = 5)
0
0
0
operation for low or high percentage of relative humidity (only if F0 = 5) (17)
0 = LOW RELATIVE HUMIDITY - the evaporator fan will operate in parallel with the compressor; see also F4 and F5
1 = HIGH RELATIVE HUMIDITY - the evaporator fan will always be switched on
5.0
5.0
5.0
evaporator temperature below limit at which the evaporator fan is disactivated (relative to working setpoint, that is "working setpoint + F7");
see also F3
2.0
2.0
2.0
parameter F1differential
0
0
delay in the switching off of evaporator fan following the switching off of the compressor (only if F0 = 2, 4 and 5)
15.0
15.0
condenser temperature above that at which the condenser fan is switched on ("F11 + 2.0 °C/4 °F , only if u1 and/or u11 = 6 and provided
the compressor is switched on); see also F12 (18)
3 0
3 0
delay in switching off of the condenser fan following the switching off of the condenser (only if u1 and/or u11 = 6); see also F11
5
5
5
time the evaporator fan remains turned off during function Energy Saving; see also F14 and i10 (only if F0 = 1 or 2)
5
5
5
time the evaporator fan remains turned on during function Energy Saving; see also F13 and i10 (only if F0 = 1 or 2)
EVX203 EVX204/5 EVX214/5
DIGITAL INPUTS
2
3
3
effect caused by the activation of the door microswitch input; see also i4
0 = no effect
1 = the compressor and evaporator fan (evaporator fan in EVX203, EVX204, EVX214, EVX205 and EVX215 only) will be switched off (at
most for time i3 or until the input is disactivated (19)
2 = the evaporator fan will be switched off (at most for time i3 or until the input is disactivated) (visible in EVX203, EVX204, EVX214, EVX205
and EVX215 only)
3 = the cell light will be switched on (only if u1 and/or u11 = 0, until the input is disactivated) (only visible in EVX204, EVX214, EVX205
and EVX215)
4 = the compressor and evaporator fan will be switched off (at most for time i3 or until the input is disactivated) and the cell light will be
switched on (only if u1 and/or u11 = 0, until the input is disactivated) (only visible in EVX204, EVX214, EVX205 and EVX215) (19)
5 = the evaporator fan will be switched off (at most until time i3 or until the input has been disactivated) and the cell light will be switched
on (only if u1 and/or u11 = 0, until the input is disactivated) (only visible in EVX204, EVX214, EVX205 and EVX215)
0
0
0
type of door microswitch input contact
0 = normally open (active input with closed contact)
1 = normally closed (active input with open contact)
3 0
3 0
3 0
delay in signaling of door microswitch input alarm (code "id")
-1= the alarm will not be signaled