MONITOR DESCRIPTION
D
escription of the RCPL-Uno connector
a. Wall fixing holes (x4).
b. Monitor fixing pins (x2).
c. Cable vertical entrance.
U
se of the end of line jumper.
E
L562 module for video installations with twisted pair.
a
b
50mm.
Colocar la parte superior de la regleta a 1,60m. del suelo.
Place the top part of the monitor connector at 1,60m. from the floor.
REF
RCPL-UNO
b
a
The end of line jumper is located in CN2 connector, in the rear part of the
monitor. In systems with twisted pair, the end of line jumper is located in
the El562 module (see next paragraph)
Do not remove jumper in those monitors where the video cable end is
located.
Remove jumper only in intermediate monitors.
Find CN2 connector in the rear part of the monitor.
Remove the existing jumper and plug the EL562 module.
NOTE: The doorpanel admits both installation types (coaxial or twisted
pair installation) without making any change.
See the specific installation diagram.
50mm.
Presionar para abrir.
Press to open.
V /MP
in
MALLA
V /VP
o
A
11784082
CODE
D
LOTE
HZ-
d. Fixing pin.
e. Cable central entrance.
f. Connection terminal block.
47
c
d
e