Door Coding System
430 - 10
External noise influences - reset key
Despite internal proofing measures exceptionally strong
noise fields can bring about a malfunction
microprocessor-controlled door coding system. Noise
influences can be prevented if the following points are heeded
during installation:
– Do not mount the unit in the immediate vicinity of
inductive power consumers.
– Lay a separate line for mains voltage supply
(possibly using a mains filter) .
– Suppress any inductive power consumers
(varistors, RC-sections).
After elimination of the noise, resetting of the door coding
system is necessary. For this purpose the reset key, which
is located on the main board, has to be pressed until the
adjacent yellow LED illuminates briefly.
Protected zone
(inside)
430 - 10
~
3
230 V / 50 - 60 Hz
NYM 3 x 1,5 mm
8

Electrical Wiring

2
Technical specifications:
Connected voltage
of the
Frequency
Power consumption
Operating voltage
Load capacity
Degree of protection
Operating temperature 0 °C to 40 °C
Inputs:
1 mains connection with earth lead
1 keypad unit (7-pole)
1 door release with check-back position indicator contacts
1 door release push-button
Outputs:
1 electric door release
(relay with zero potential alternating contact)
1 erroneous code relay
(relay with zero potential alternating contact)
All relay contacts can be subjected to a maximum load
of 65 V/2 A.
8
screened
200 mtrs max.
4
screened
2
screened
e n g l i s h
230 V AC + 10 % / - 10 %
50 - 60 Hz
21 W max.
12 V
600 mA max. for external power
consumers (e.g. door releases)
IP 20
keypad unit
7 8 9
4 5 6
1 2 3
+ 0 –
electric door release
door release push-button
®