Door Coding System
430 - 10
General description
The fully electronic/microprocessor-controlled door coding
system model 430-10 in the single channel version provides
facilities for the connection of one door (door release) and
one keypad. Residing in a robust sheet steel enclosure the
control device comprises the door coding electronics and
the power unit. The control device is protected against
manipulation by unauthorized persons by means of a
lockable front door.
The keypad is usually mounted within hand reach of the
door and the control device in the protected area inside the
building. The electric door release is fitted into the door
frame in the form of a counterpart to the door lock.
Function:
The 4-digit code number entered via the keypad are
converted into electrical signals and passed on to the control
device. There it is decided as to access entitlement by
comparing the signals with the prespecified code number.
If this is positive the door release output relay will switch to
release for a time period (door unlocking period) that has
been preset in the control device.
The 4-digit code number can be altered at any time using
the 4 code switches arranged on the main circuit board.
Keypads
Keypads are always mounted within hand reach of doors.
The keypad enclosure can be conveniently fitted by un-
screwing and removing the front panel. Introduction and
connection of the 7-conductor screened control cable (see
connection diagram) is now possible. When the front panel
is subsequently screwed back on, in the case of keypads
protected against water, care must be taken that the seal is
not damaged. Screened cable with a minimum of 7
conductors is required to be used for the keypad control
cable. A lead length between keypad and control device of
200 m may not be exceeded. Outgoing from the door coding
system all leads must be laid separately.
A choice of several different keypad units is available.
Common to all is that they have a 12-key matrix keypad.
In detail the following keypads are available:
412-12
keypad unit
- surface mounted version
413-12
keypad unit
- surface mounted,
protected against water
414-12
keypad unit
- concealed mounting
415-12
keypad unit
- concealed mounting,
protected against water
6
Door releases
The door releases to be utilized together with the door coding
system are the models 1405 RR/1705 RR (energized mode)
and 3405 RR/3705 RR (nonenergized mode). It is re-
commended fundamentally that the door release be used
together with check-back position indicator contacts (orde-
ring suffix RR). The electrical lead connection between the
door coding system and the electrical door release must be
effected using screened cable.
Door release in energized mode:
The energized mode door release, e.g. 1405 RR, is unlocked
when under voltage. In the event of a power failure the
locking security of the door is guaranteed.
Door release in nonenergized mode:
The nonenergized mode door release, e.g. 3405 RR, is
unlocked when not under voltage. In the event of a power
failure the door provides absolutely free access.
Security door release
In the case of enhanced security requirements it is re-
commended that security door release model 14105 RR
(energized mode) or 34105 RR (nonenergized mode) be
fitted. These security door releases have a pressure
resistance of > 15 KN to break-in attempts.
Door release with check-back
position indicator contacts,
ordering suffix ...RR
Automatic resetting of the door release relay when the
door is opened. Thus the subsequently closed door is
immediately relocked.
Technical specifications:
1405 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 200 mA, continuous duty
1705 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 230 mA, continuous duty
3405 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 200 mA, continuous duty
3705 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 230 mA, continuous duty
14105 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 400 mA, continuous duty
34105 RR voltage rating 12 V (voltage tolerance 11 - 13 V)
power consumption 470 mA, continuous duty