ALARM INPUT

Possibly connect a sensor to the auxiliary input IN1. The input is referred to ground (-) and can be programmed
as NC, NO, Single balancing and Double balancing. The input can also manage fast signals coming from seismic
sensors or rolling shutters; in this case, the connecting mode is fixed on NC. In order to connect with balancing
use the provided 2.7kohm resistors with 1% tolerance.
WARNING! "Double balance" is the only EN50131 compliant connection mode. Refer to the manuals of
1068 series control units for further, more detailed information.
EN50131

TECHNICAL CHARACTERISTICS

Nominal supply voltage (taken from the control unit via a communication bus) ............................... 13.8 Vdc
Min/max operation voltage .................................................................................................... 9 Vdc ÷ 15 Vdc
Nominal current absorbed at 13.8 Vdc:
In stand-by, only LED for presence mains supply ............................................................................... 17 mA
Operative, with backlighting at minimum value ................................................................................... 22 mA
Operative, with backlighting at maximum value and all LEDs ON ....................................................... 93 mA
Programmable input ................................................................................................................................... 1
Degree of protection of casing ..................................................................................................... IP40 / IK06
Dimensions (L x H x D) in mm ............................................................................................... 141 x 117 x 29
4