General Description - Urmet 1068/21 Livret D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

GENERAL DESCRIPTION

The 1068/021 indoor display keypad, used to control and program the 1068 series system is equipped with :
LCD backlit display with contrast and luminosity regulation;
3 LED to signal the system status (Power supply, Recommendations, Zone status);
18 door-protected alphanumerical keys;
buzzer with adjustable volume;
1 programmable input.
A tamper jumper is supplied with the product to bypass the keypad opening/removal button. Use of this
feature will cancel EN50131 certification.
The keypad is powered by the bus that connects it to the control panel.
WARNING! In this document there are only present some essential indications about product.
For further and more detailed information, refer to manuals concerning 1068 series control panels.
POSITIONING
Keypad must be positioned:
 in an environment that is sheltered and protected from water and humidity;
 on a dry and level wall;
 in the vicinity of the accesses to area to be protected;
 in an inner location which is not subjected to excessive sudden
rises/falls in temperature, and is protected by anti-burglar system; at
160 cm height for normal installations. For disabled or special needs
users of the D1 type (elderly) and D2 type (lower limb motor
difficulties), the centre of the device must be arranged at a height comprised between 75 cm and 140
cm with respect to the floor. For more details, see technical standard CEI 64-21:2016-12 – Residential
environments. Systems suited for use by people with disabilities or special needs.
KEYPAD OPENING
Use a slotted screwdriver to open the keypad by gently pressing the point indicated in the image in order to
disengage the closure spur and lift the cover (Fig. 1).
INSTALLATION
 For running the cables, open the provided hole on the bottom of the keypad (D - Fig. 2). Otherwise, the
scored holes for the cable ducts can be used (E - Fig. 2).
 Secure the keypad bottom to the wall by means of 6 mm plugs (A/B - Fig. 2 - not provided). During fixing
always use also the hole (C - Fig. 2) for the protection against removal.
 If bottom is fastened over round or rectangular a 3-place built-in box (e.g. BTICINO 503), use holes (A or B)
and suitable screws.
WARNING! before fixing, verify the bottom direction: cover closing hook shall be positioned at the
bottom.
 For easier wiring, it is advisable to strip the cable as far as the access hole.
2