SPE
Interface
Keys:
,
,
,
Key:
Key:
Key:
Key:
Key:
Key:
98
,
,
COM1:
0 - serial interface Off.
1 - serial interface On.
2 - serial Interface On, no error message occurs in case of a transmission error.
Baud rate:
Indication of bits which are transferred per second.
Following values are possible: 1200, 2400, 4800, 9600, 19200, 38400 and 57600.
P = Parity:
N - No parity; E - Even; O - Odd
Please observe that the settings correspond to those of the print module.
D = Data bits
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
COM2:
0 - serial interface Off.
1 - serial interface On.
2 - serial Interface On, no error message occurs in case of a transmission error.
Baud rate:
Indication of bits which are transferred per second.
Following values are possible: 1200, 2400, 4800, 9600, 19200, 38400 and 57600.
P = Parity:
N - No parity; E - Even; O - Odd
Please observe that the settings correspond to those of the print module.
D = Data bits
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
SOH: Start of data transfer block
ETB: End of data transfer block
Data memory:
Standard: After starting a print order the printer buffer receives data as long as it is filled.
Advanced: During a current print order data is received and processed.
Off: After starting a print order no more data is received.
Parallel port:
SPP - Standard Parallel Port
ECP - Extended Capabilities Port (grants a fast data transmission but it is only to set at PCs of
newer version).
Please observe that the settings correspond to those of the PC.
Port test:
Check whether the data are transferred via the interface.
Press the
and
keys to select standard (on). Press the
any port (COM1, LPT, USB, TCP/IP) is printed.
English
Hex format 01
Hex formal 17
key and the data sent via