man_TBH570-3-TBH572-3 ('21) V1.indd 147
man_TBH570-3-TBH572-3 ('21) V1.indd 147
To light the fire, place "firelighters" on the bottom of the brazier. Light the fire-
lighter with a match and wait 1 minute before lighting the stove using the "stan-
dard start-up procedure" as described in section 4.2.
If this does not result in a properly burning fire, the stoves setup parameters will
need to be changed by a professional. Contact a Tectro-approved fitter.
4.4 SETTING THE TEMPERATURE
1.
Push button 1 to go to the temperature setting menu. The display will show
"set" and the desired temperature.
2.
Press button 1 to reduce the desired temperature. The display will show set
temperature.
3.
Press button 2 to raise the desired temperature. The display will show set
temperature.
4.
The desired temperature has now been set. After 3 seconds, the display will
automatically return to normal operating mode.
5.
The procedure for changing the temperature is now complete.
6.
The desired temperature can also be set using the remote control. See sec-
tion 4.8 for instructions on using the remote control.
The desired temperature can be set anywhere between 7ºC and 40ºC.
4.5
CHANGING THE HEAT OUTPUT OF THE STOVE
1.
Push button 2 once. The display will show "pot" and one of the 5 heat out-
put levels.
2.
Push button 1 to reduce the heat output setting. The display will show the
new output setting.
3.
Push button 2 to raise the heat output setting. The display will show the
new output setting.
4.
Once the display has shown the new output setting, 3 seconds later the dis-
play will automatically return to normal operating mode.
5.
The procedure for changing the heat output setting is now complete.
6.
The desired heat output can also be set using the remote control. See sec-
tion 4.7 for instructions on using the remote control.
4.6 STANDARD SHUT-DOWN
The stove can be switched off by pressing button 3 until "OFF" appears in the dis-
play. During the shutdown phase, the supply of wood pellets to the combustion
chamber is stopped and the room air circulation blower is switched off. The smoke
extraction blower will continue to run for a short time, switching off after the
cooling-down phase.
4
147
13-07-2021 13:38
13-07-2021 13:38