6. Attach Lower Yoke
Attach the lower yoke to the bottom of the extension
tube with the Lower Yoke Hardware as shown. Tighten
the hardware so that it is snug, but not fully tightened.
Lower Yoke Hardware:
a. (2) 1/2-13 x 4-1/2'' GR 8 Bolt
b. (4) 1/2'' Flat Washer
c. (2) 1/2-13 Nylock Nut
7. Attach Main Fan Unit
CAUTION: The main fan unit is heavy. Use caution
when raising it.
Attach the main fan unit to the lower yoke with the
Main Fan Unit Hardware. Do not rest the main fan unit
on the ground! Make sure the lower cable is positioned
between the lower yoke brackets as shown on the right.
Tighten the bolts to 40 ft·lb (54.2 N·m) using a torque
wrench and 3/4" socket. Do not discard the main fan unit
packaging. It should be used if the fan is ever moved or
relocated.
Main Fan Unit Hardware:
a. (4) 1/2-13 x 1-3/4" GR 8 Bolt
b. (8) 1/2'' Flat Washer
c. (4) 1/2-13 Nylock Nut
8. Confirm Orientation
After securing the main fan unit to the lower yoke, allow the fan to hang
so that the extension tube is plumb to the ground. When it is properly
positioned, fully tighten all mounting hardware to 40 ft·lb (54.2 N·m).
18
WWW.BIGASSSOLUTIONS.COM
© 2015 DELTA T CORP.
c
b
a
b
b
c
ALL RIGHTS RESERVED.
b
a