OE 0900
HGV INDUCTION HEATER
HEATING TIMER
The timer automatically stops the heating after a certain time, which allows a precise
adjustment of the energy (heat) introduced into the material, for example, for spot or
repeated heating to a defined temperature.
Press the switch several times until the TIMER indicator lights up red
desired heating time in seconds or turn off the timer by selecting "OFF".
If the timer is set, the indicator light lights up green
the heating is stopped by the timer, the indicator light starts flashing green
display shows the letters "OFF" when the button is released. When the button is released,
the heating stops immediately..
Note: If the heating has started in the timer settings, the display shows the remaining heating
time (countdown of the remaining heating time).
Note: Press the switch to access the preheat/program settings (see next chapter). To
immediately exit the power settings, press and hold the switch
• Settings :
Description
Return/exit
Power transmitted
Output power
Power factor
Frequency
Input current
Output current
Input voltage
Cooling temperature
Limitation
Note: See the list of errors in the appendix.
Indicator lamp
Red
Red, flashing
Green, flashing
Display
---
P
Po
PF
FrE
OC
IC
VOL
tEP
OL
Errors
Err
when the heating starts, and if
Statuts
Heating time settings
Current reading during the heating
Latest reading
Value unit
---
0,01kW
0,01kVA
1%
0,1kHz
0,1A
0,1A
Vrms
0,1°C
--- = no limitation
PO = max. power transmitted
IC = max. input current
OC = max. output current
DUT = max. inverter duty
TE = temperature
Error history
. Turn to set the
and the