OE 0900
HGV INDUCTION HEATER
ACTIVATING THE DEVICE
• Check the coolant level and fill it if necessary.
• Connect the unit to an electrical outlet and turn it on using the switch on the back of the
unit.
• The unit's auto diagnosis is automatically started and the cooling system is purged; the
letters "FIL" flash on the display during this time.
• If the unit detects a lack of coolant, it displays the message
Error E12: In this case, fill with coolant (SA 0901).
• If everything is in order, the device switches to "STAND BY".
STAND BY
This is the initial state of the device, which allows the encoder to be turned to set the desired
heating power or temperature, depending on the mode selected:
• Controlled power mode (CP), the indicator light lights up red
heating power as a % of the maximum heating power and the unit automatically sets the
parameters necessary to maintain the set power.
• Controlled magnetic field (CF) mode, the indicator light lights up green
the desired field strength in % of the maximum field strength and the device automatically
maintains the set field strength.
The indicator light flashes during heating and the display shows the current power values
in kW.
The desired heating mode can be set in the settings or selected by pressing and holding
the switch - the name of the corresponding CP/CF mode appears on the display and the
indicator light changes color.
Press the switch to switch to other settings of the device parameters, such as the heating
timer, etc.
Note: If the power supply is remote controlled, the letters "rc" are displayed for 3 seconds
by turning the switch.
Indicator lamp
Red
Heating power setting in %, CP mode
Red, flashing
Power reading in kW during the heating
Green
Green, flashing
Power reading in kW during the heating
- the user sets the desired
Statuts
Magnetic field intensity setting in %,
CF mode
- the user sets