Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of a public area*)
with manned operation
A
with visible impulses
C
(e.g. sensor)
with not visible impulses
C
(e.g. transmitter)
automatic
C and D
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated), like code
ACG2013.
B: Key selector with manned operation, like code ACG1010.
C: Built-in Encoder (operating as thrust limitation device, within the limits indicated by
specification EN12453 - Appendix A).
D: Built-in Encoder (operating as presence detector).
A- ELECTRIC CONNECTION

POWER SUPPLY

230Vac 50Hz
TRANSFORMER
ANTENNA
ANTENNA
433 MHz
BRAIDING
Manuali online interattivi
Manuels interactifs en ligne
Interactive online manuals
Interaktive Online-Handbücher
Manuales interactivos en línea.
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
-
C
C and D
C and D
C and D
C and D
C and D
BLINKER
FUSE
24Vdc 20W
1,6A
M
ENCODER
A+TEST / A-
PHOTOCELLS AUTO-TEST
OR
ENERGY SAVING
LED
(LOW BATTERY)
24Vdc 3W
WITH BATTERY OPERATION
29
P1 24V code AC08084
SECURITY LOCK
COMMON
OK CLOSE
TIMER
START
CLOSE
OPEN 2
OPEN 1
G