Technical information ACCESS-IT UNIT
STANDARD TYPE 2
READER
For the BioFx485 type reader you must enter its identifier (ID on the product serial number label and
its security level (false acceptance rate) and its sensitivity level (detection of the presence of a finger
on the sensor).
CONFIGURE
READER 1
Scroll through the different numbers, using the "+" and "-" keys. The "V" key is used to confirm
a parameter. The "C" key cancels the entered parameter.
This menu comprises:
NEUTRAL APB
BEHAVIOUR
OPENINGCONTROL?
NEUTRAL
OPENING TIME?
5 SEC.
PUSH BUTTON
DEACTIVATED
DOOR CONTACT
DEACTIVATED
Profile of the different readers. Each reader can function differently depending on the control unit's
current alert level. For this you have three configurable profiles (one per alert level), as follows:
Profile 1:
READER STATUS:
AUTO MODE
FREE ACCESS?
DEACTIVATED
Profile 2 then 3: identical to profile 1
CONFIGURE
READER 2
This menu allows the configuration of reader 2 identical to reader 1.
DEVICE
TIME PERIODS
Same as the previous menu.
Configure reader 1
Allows the definition of reader 1 for entry and exit.
By default the reader is neutral.
Allows indication of the output to be used to control
an opening device.
Allows adjustment of the delay during which the relay
will be activated (between 1 and 255 seconds for pulse
or bistable mode).
Allows definition of the input used for the push
button.
Same as the push button but for the door contact.
Reader status (Automatic mode / Maintained open /
Maintained closed).
Reader free access time range (select here a device
time range).
Configure reader 2
Automated devices time periods (and free access)
p.38/42