RIB RAPID S Instructions D'installation page 31

Masquer les pouces Voir aussi pour RAPID S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

F
UNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF)
OPEN1 BUTTON (COM - OPEN1)
The OPEN1 button performs the open command,
regardless the position of the boom arm. If the OPEN1
button is pressed during the closing, the boom arm stops
and will reverse the movement in opening.
In PARK MODE (DIP6 ON), if there is a vehicle at
the entry (see scheme 4) and the TLC contact is closed,
the OPEN1 command opens the barrier. Otherwise,
if the TLC contact is open the OPEN1 command is
disabled.
CLOCK FUNCTION
The Clock Function permits to keep the boom arm
opened even if, for example, the Automatic Closing
is enabled (DIP3 ON) or somebody commands the
barrier closing. It is useful during rush hour, when
traffic is heavy and the flow is low (e.g. entrance/exit
of employees, emergencies in residential areas or car
parks) and it's necessary to keep the boom arm opened.
It can be done by connecting a switch and/or a daily/
weekly timer either in parallel to the OPEN1 button or
instead of the OPEN1 button. When the control board
receives this command, the boom arm will open and
by keeping this contact closed for all the time of the
boom arm opening, the Clock Function is automatically
activated.
In fact, once reached the open position, the barrier will
remain opened and all of the control board features are
blocked. Only when the OPEN1 button is released, the
control board functions are re-activated and the boom
arm will close immediately.
CLOSE BUTTON (COM - CLOSE)
The CLOSE button performs the close command,
regardless the position of the boom arm.
STEP BY STEP or AUTOMATIC COMMANDS (COM - K BUTT)
DIP5 - OFF => The K BUTT performs the cyclic command open-stop-close-stop-open etc.
DIP5 - ON => The K BUTT performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
REMOTE CONTROL
DIP4 - OFF => The REMOTE CONTROL performs the cyclic command open-stop-close-
O
PERATING IN PARK MODE (DIP6 ON)
TO ENTER:
Provided there be a vehicle on the Entry magnetic loop (see
scheme 4), opening can be controlled by pressing OPEN1,
K BUTT or RADIO switch (OPEN1 performs the boom arm
opening only if the TLC, connected to the Entry Magnetic Loop,
contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic loop (see
scheme 4), opening can be controlled by pressing OPEN2, K
BUTT, RADIO switch. The OPEN2 can be connected to the
Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform the barrier
opening regardless the presence of a vehicle at the Entry.
If the DIP8 is turned OFF, the OPEN2 will perform the barrier
opening if there is no vehicle on the magnetic sensor connected
to the TLC input (TLC contact opened).
In both the conditions, TO ENTER and TO EXIT, from the
complete boom arm open position:
If the Automatic Closing is enabled (DIP3 ON), the boom
arm will close at the end of the delay time programmed (see
Point D).
If the Automatic Closing is disabled, the boom arm will
remain open until a closing command is pressed or until the
vehicle passes in front of the photocells, giving an OK CLOSE
impulse to the control board (the OK CLOSE command can be
connected to the NO contact of the photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the
OPEN2 command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will
perform the boom arm opening depending on the switch DIP8 position.
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will perform the boom arm opening
regardless the state of the TLC input.
If DIP8 is turned OFF and PARK MODE is enabled, OPEN2 will perform the boom arm opening
only if the TLC contact is OPEN (no vehicle at the Entry, see scheme 4).
OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE)
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
LSSC
LSSO
TIMER
AERIAL
+
+
BUZZER
K BUTTON
LED
R=2K2
-
STOP
CLOSE
+
OPEN 1
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
stop-open etc.
DIP4 - ON => The REMOTE CONTROL performs:
- the open command, if pressed with the barrier completely closed
- the close command, if pressed with the barrier completely opened
- no effect, if pressed during the barrier opening
- the boom arm re-open, if pressed while the barrier is closing
AUTOMATIC CLOSING (DIP3 ON)
The Automatic Closing from the complete open position can be enabled turning ON the
DIP3. The maximum time that can be programmed is 5 minutes (see point D).
COAX
_
+
_
+
If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OKCLOSE will perform the boom arm closure after
the vehicle transit.
Usually, this command is connected to the Normally Open contact from a photocell receiver or a
magnetic sensor device installed along the boom arm closing line. The vehicle will engage the contact
when it reaches the closing line. The boom arm will close as soon as the vehicle left the closing line
and the contact is released.
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
MAGNETIC LOOP
TO ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
G
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rapid s metalAa50070kAa50079k

Table des Matières