G
B
RELAY AND MOTOR COMMAND
K1 => Opening direction command
K2 => Closure direction command
Q4 => TRIAC - Opening and Closing motor command
Q5 => Blinker command
POINT B
- SETTINGS
DIP 1 (ON)
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2 (ON)
PROGRAMMING (See Point D)
DIP 1-2
STORING/ERASING RADIO CODES FOR MOTOR
CONTROL (only CRX control board) (See Point E)
DIP 3
ON - Automatic Closing ENABLED (max 5 min)
OFF - Automatic Closing DISABLED
DIP 4
ON - AUTOMATIC Radio Receiver Command
OFF - STEP BY STEP Radio Receiver Command
DIP 5
ON - AUTOMATIC single pulse command (K BUTT.)
OFF - STEP BY STEP single pulse command (K BUTT.)
DIP 6
ON - Operation in PARK MODE
OFF - Operation in NORMAL MODE
WARNING: The PARK MODE enables or disables some features and
commands:
If NORMAL MODE is enabled, OPEN2 command, OK CLOSE
command and TLC (Traffic Light Control) input, are not enabled.
If PARK MODE is enabled all commands are enabled.
DIP 7
ON - boom arm locking magnet ENABLED (ACQ9080 or ACQ9081
optional cards)
OFF - courtesy light operation ENABLED (ACQ9080 or ACQ9081
optional cards)
If none of the optional card is connected, turn DIP7 to OFF.
DIP 8
ON - in PARK MODE the OPEN2 button is always enabled
OFF - in PARK MODE the OPEN2 button works if there is no vehicle
on the magnetic sensor connected to the TLC input (TLC contact
opened).
DIP 9
ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 10 ON - after the blackout the boom arm automatically closes
OFF - after the blackout the boom arm remains still on the point it was
when blackout occurred
DIP 11 OFF for RAPID S barrier
DIP 12
Operation control with low speed limit switches connected
OFF -
separately LIMIT SWITCHES FIXED ON THE BALANCE
SPRING BARS
Operation control with low speed limit switches connected in
ON
-
parallel LIMIT SWITCHES FIXED ON THE DRIVING SHAFT (the
low speed wire can be connected to LSSC or LSSO)
DIP 13 ON - Blinker operation with intermittent power supply
OFF - Blinker operation with fixed power supply
DIP 14 DIP 15 DIP16 STANDARD BARRIER
OFF
OFF
OFF
RAPID S code AA50070
OFF
OFF
ON
RAPID S code AA50070
ON
OFF
ON
RAPID S code AA50070
LOW SPEED REGULATOR
Slow-speed regulations are carried out by turning the Trimmer LOW SPEED,
it permits to vary the speed of the motor in approaching to the closing position
(turning clockwise to increase the motor speed). This kind of regulation is not
available in approaching to the opening position.
The starting of slowing down is controlled automatically by the limit switches at
approximately 30° before reaching the complete opening and closing position.
LED WARNING
DL1 - Programming activated (red)
DL2 - Stop contact (red)
DL3 - Barrier opening (green)
DL4 - Barrier closing (red)
DL5 - Photocells contact (red)
DL6 - Safety strip contact (red)
DL7 - Closing limit switch contact (red)
DL8 - Opening limit switch contact (red)
DL9 - Radio programming activated (green) (CRX models only)
(for PARK control panel)
with a 3m boom arm code ACG8501
with a 4m boom arm code ACG8502
with a 5m boom arm code ACG8503
POINT C
- CALIBRATING LOW SPEED MOTOR
This check is meant to facilitate the installer during the start-up of the system or for
any other future controls:
1 - Turn DIP1 to ON, the red led DL1 starts blinking
2 - Press the PROG button and hold it (movement is now performed in "man
present" mode, open-stop-close-stop-open etc.).
If the GREEN led DL3 is on, the boom arm opens. If the RED led DL3 is on,
the boom arm closes.
3 - Carry out the slow-down speed calibration:
- Turn the LOW SPEED trimmer to minimum
- Press and hold the PROG button pressed
- Check whether the low speed has been enabled once LSSC and LSSO limit
switches have been reached
- Adjust the LOW SPEED trimmer
WARNING: Make sure the motor is powerful enough to move the bar during
closure. Otherwise increase the value set on the LOW SPEED trimmer until it
reaches the ideal operation condition.
4 - Turn DIP1 to OFF, the red LED DL1 turns off.
During Point C procedure the safety-strip and photocells are not enabled.
POINT D
- TIME PROGRAMMING
1 - Close the barrier completely.
2 - Turn the DIP 2 to ON, the red led DL1 starts blinking.
3 - Press the PROG button, the boom arm opens.
4 - Once opening has been completed, the boom arm stops. The gap of time
between now (stop of the motor) and the next pressing of the PROG button (see
step 5 below) will be then stored as waiting time (max 5 minutes) for Automatic
Closing feature.
5 - Press the PROG button, the boom arm closes and the Automatic Closing time
is stored (see DIP3 function to enable or disable the Automatic Closing feature).
6 - The red LED DL1 turns off.
7 - Turn DIP2 to OFF.
During Point D procedure, the safety devices (photocells and safety strip)
are active.
POINT E
- RADIO CODE STORING (ONLY FOR CRX) (MAX 60
CODES)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking
slowly. Each code must be programmed within 10 seconds.
4 - Press one of the buttons on the remote control (usually channel A). If the
remote control is stored correctly green LED DL9 (on the PARK230V CRX
control board) emits a flash. The 10 seconds' time within storing radio codes is
automatically renewed to allow the string of the next remote control.
5 - To end radio code storing either press PROG button or let 10 seconds pass.
The LED DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
POINT F
- RADIO CODE ERASING (ONLY FOR CRX)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking
slowly. Code erasing must be carried out within 10 seconds.
4 - Press the PROG button and hold it for 5 seconds, the total memory erasing
will be indicated by two flashes of the green LED DL9.
The red LED DL1 will blink for 10 seconds and it will be possible to store new
radio codes following the Point E procedure described above.
5 - To end radio code storing either press PROG button or let 10 seconds pass.
The LED DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
POINT G
- RADIO CODE FULL MEMORY TEST (ONLY FOR
CRX)
1 - The boom arm must be completely closed.
2 - Turn DIP1 to ON position, the red LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the red LED DL1 starts blinking
slowly.
If the green LED DL9 flashes six times, it means that the radio code memory is
FULL (maximum codes to be stored 60).
6 - Turn DIP1 to OFF position.