ATTACH THE SUPPORT
1. Put a thick, protective
covering over cooktop,
set-in range or countertop
to protect from damage
or dirt.
2. Determine and clearly
mark with a pencil on the
ceiling where the rangehood
.
will be installed.
3. A template (L in FIGURE
7) for mounting the support
is supplied in the carton
with the support. Use this
template to mark holes for
support on the ceiling.
4. Determine and make necessary cuts for the ductwork. The duct
opening is shown on the mounting template (L in FIGURE 7). Install
ductwork before mounting the support.
5. If using the High Ceiling Chimney Kit, remove the CHIMNEY
COVER from the CHIMNEY EXTENSION (A in FIGURE 8). Position
the CHIMNEY EXTENSION over the CHIMNEY SUPPORT (B in
FIGURE 8) so that the outside edges and the electrical holes line up.
Attach the CHIMNEY EXTENSION to the CHIMNEY SUPPORT using
the 4 bolts (C in FIGURE 8). Tighten bolts securely.
6. Determine the proper location for the Power Supply Cable as
indicated on the template. Use a 1 1/4" Drill Bit to make this hole. Run
the Power Supply Cable. Use caulking to seal around the hole. DO
NOT turn on the power until installation is complete! A knockout
is provided at the top of the CHIMNEY SUPPORT.
7. For ducted installations, place the round DAMPER (N in FIGURE
1) into the exhaust opening of the rangehood and press down.
FIGURE 7
FIGURE 8
A. 1/4"
FIGURE 9
8. Install in previously drilled pilot holes in the ceiling the 4 bolts,
washers and nuts OR the wood screws from the parts bag depending
on your ceiling type (PAGE 4). Leave screw heads about ¹⁄4" away
from ceiling joists (A IN FIGURE 9).
9. Remove wiring box cover located on the top section of the chimney
support.
10. Install a UL or CSA listed strain relief in the wiring box so that the
screws can be tightened after the chimney support is
attached to the ceiling.
11. Lift chimney support into its final position, feeding electrical wire
through the strain relief.
12. Position the chimney support so that the large end of the
keyhole slots are over the ceiling attachment bolts (B IN FIGURE 9).
Then push the chimney support so that the bolts are in the neck of
the slots. (C IN FIGURE 9) Tighten bolts securely.
IMPORTANT: The chimney support must be securely
attached to the ceiling.
13. Determine the desired length of the support structure and adjust
the length of the support by removing the four screws (indicated
in FIGURE 10) with a flat head screwdriver. Once the length of the
support is determined, install and tighten the four screws.
C
B
FIGURE 10