Evaluation Unit CMS-E-ER
Operating voltage connection
UB
0V
A1
A2
Betriebsspannung/
operating voltage
Wiring diagram for one read head CMS-R-...
H22
1 Lesekopf/1 read head
Wiring diagram for two read heads CMS-R-...
Lesekopf 1/
read head 1
BN
WH
BU
H11
H12
H73
2 Leseköpfe/2 read heads
Wiring diagram for > 2 up to 30 read heads CMS-R-...
Lesekopf 1/
Lesekopf 2/
read head 1
read head 2
BN
WH
BU
BK
BN
WH
BU
H22
H11
H73
H74
>2 bis 30 Leseköpfe/>2 up to 30 read heads
Figure 2: Wiring diagram CMS-E-ER
Connection for automatic start
Connection for automatic start
without feedback loop
Rückführkreis
feedback loop
Y1
Y2
Y3
BN
WH
BU
BK
H11
H12
H73
H74
Lesekopf 2/
read head 1
BK
BN
WH
BU
BK
H74
H22
Lesekopf 3/
Lesekopf n/
read head 3
read head n
BK
BN
WH
BU
BK
BN
WH
...
H12
UB
A1
H11
H12
Leseköpfe/read heads
CMS
A2
0V
Manual start using start button
with feedback loop
with falling edge and connected
Rückführkreis/
feedback loop
Y1
Y2
Y3
Wiring diagram for one read head CMS-RH-...
Wiring diagram for two read heads CMS-RH-...
Lesekopf 1/read head 1
PK
BN
1
H11
Wiring diagram for > 2 up to 30 read heads CMS-RH-...
Lesekopf 1/read head 1
BU
BK
PK
BN
WH
BU
BK
+
-
1
2
3
4
5
H11
H12
H73
H74
>2 bis 30 Leseköpfe/>2 up to 30 read heads
Wiring diagram CMS-E-ER
Sicherheits-
kontakte/
H73
H74
H22
13
23
safety
contacts
1-2
Rückführkreis/
feedback loop
Y1
Y2
Y3
14
24
8
Manual start using start button
with rising edge and connected
feedback loop
feedback loop
Rückführkreis/
Rückführkreis/
feedback loop
feedback loop
Y1
Y1
Y2
Y3
Lesekopf/read head
PK
BN
WH
BU
BK
+
-
1
2
3
4
5
H11
H12
H73
H74
H22
1 Lesekopf/1 read head
Lesekopf 2/read head 2
WH
BU
BK
PK
BN
WH
BU
+
-
+
2
3
4
5
6
7
8
9
H12
H73
H74
H22
2 Leseköpfe/2 read heads
Lesekopf 2/read head 2
PK
BN
WH
BU
BK
+
-
6
7
8
9
10
...
H22
Hilfs-
kontakt/
31
auxiliary
contacts
The following applies to all the illustrations:
Evaluation unit electrically isolated
f
32
Actuator not in the operating distance
f
Y2
Y3
BK
-
10
Lesekopf n/read head n
PK
BN
WH
BU
BK
+
-
11 12 13
14
15

Publicité